2022-02-28 18:14:15NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21071257
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
  
 1- OK
 2- OK
 3- OK
 4- OK.
 5- OK.
 6- OK.
 7- OK.
 8- OK.
 9- OK.
 10- OK.
  
 11-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)ENTRY DOOR OK W/ REVISED DESIGN PRESSURES.
 B)SLIDING GLASS DOORS. OK.
 C)SINGLE HUNG WINDOWS. OK.
  
 ORIGINAL COMMENT:
 D)METAL ROOF. AND, CLEARLY SPECIFY FASTENING METHOD.
  
 RESPONSE:
 RESPONSE LETTER (NOT BY THE ENGINEER OF RECORD) IS
 INCORRECT. TABLES ON PRODUCT APPROVAL ARE BASED ON THE
 DESIGN WIND SPEED FOR THE PROJECT LOCATION. THE DESIGN
 WIND SPEED FOR THIS PROJECT IS 170 MPH ULTIMATE. THESE
 ARE THE PARAMETERS TO USE THESE TABLES NOT THE NOMINAL
 WIND SPEED OF 132 MPH. THEREFORE, THE ORIGINAL COMMENT
 APPLIES. SEE BELOW.
  
 ACCORDING TO PRODUCT APPROVAL FL27985.06 THE FASTENING
 METHOD IS NOT RATED (NR) FOR ROOF ZONES 2 AND 3. A
 DESIGN PROFESSIONAL IS REQUIRED TO PROVIDE CALCULATIONS
 FOR FASTENING AT THESE ROOF ZONES. SEE FASTENING TABLES
 ON PAGE 3 OF METAL ROOFING INSTALLATION INSTRUCTIONS.
 PROVIDE SIGNED AND SEALED CALCULATIONS OR PROVIDE
 ANOTHER PRODUCT APPROVAL THAT MEETS THE DESIGN
 PRESSURES FOR ALL ROOF ZONES.
  
 E)WINDOW MULLIONS. OK.
 F)ROOFING UNDERLAYMENT OK.
 G)ALUMINUM SOFFIT OK.
  
 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) REVISED METAL ROOF PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,