2021-08-30 15:10:25 | BUILDING PLAN REVIEW |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/RPX306 |
| INSPECTOR BN4338 |
| BUILDING OFFICIAL BU1635 |
| ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| DEVELOPMENT SERVICES DEPARTMENT |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| 2017 NEC |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE BUILDING DESIGN PARAMETERS: |
| |
| PROJECT DATA/DESIGN PARAMETERS |
| 1&2 FAMILY |
| |
| |
| 1. PROVIDE PROJECT DATA / DESIGN PARAMETERS: |
| (AS APPLICABLE) |
| |
| PROJECT DATA: 1&2 FAMILY DWELLING UNIT |
| |
| SITE PLAN/SURVEY |
| DRAINAGE PLAN: (IF APPLICABLE) |
| SCOPE OF WORK: |
| PROPERTY INFO: |
| PCN #: |
| FLOOD ZONE: (IF APPLICABLE) |
| FINISHED FLOOR ELEVATION: (IF APPLICABLE) |
| |
| GOVERNING CODES: (AS APPLICABLE) |
| |
| 2017 FLORIDA BUILDING CODE 6TH EDITION |
| 2017 FBC RESIDENTIAL BUILDING CODE ? |
| MECHANICAL/ELECTRICAL/PLUMBING/FUEL GAS |
| 2017 FBC EXISTING BUILDING CODE |
| 2014 NEC |
| |
| DESIGN PARAMETERS: |
| |
| SITE SPECIFIC DESIGN WIND LOADS PER ASCE 7-10 |
| (VULT 170MPH 3 SEC GUST / VASD 132MPH) |
| EXPOSURE CLASSIFICATION ? C |
| RISK CATEGORY ? 2 |
| STRUCTURE - ENCLOSED / OPEN |
| MRH ? |
| BUILDING CLASSIFICATION ? VB |
| OCCUPANCY CLASSIFICATION ? R3 SFR |
| |
| CLASSIFICATION OF WORK: ALTERATION LEVEL III |
| |
| 2. PROVIDE DESIGN PRESSURES FOR WINOWS/DOORS/ROOFS |
| |
| WINDOWS AND DOORS ? ZONE 4 INT. / ZONE 5 CORNER |
| (POSITVE/NEGATIVE) |
| |
| FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN |
| PRESSURES PURSUANT TO FBC-R301.2. |
| |
| R301.2.1 WIND DESIGN CRITERIA. |
| BUILDINGS AND PORTIONS THEREOF SHALL BE CONSTRUCTED IN |
| ACCORDANCE WITH THE WIND PROVISIONS OF THIS CODE USING |
| THE BASIC WIND SPEED IN TABLE R301.2(1) AS DETERMINED |
| FROM FIGURE R301.2(4). |
| |
| 3. PROVIDE ADDITIONAL SQUARE FOOTAGE UNDER AIR. |
| CANNOT ESTIMATED VALUE. |
| ADD DEMENSIONS TO GROUND FLOOR FRAMING PLAN. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 4. PROVIDE A SURVEY AND SITE DRAINAGE PLAN. |
| PROVIDE A SITE PLAN/DRAINAGE PLAN/SURVEY |
| 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED |
| WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY |
| A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF |
| NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES |
| AND THE PROPOSED FINISHED GRADES, DEPICTING THE |
| PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD |
| AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT |
| SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| INCLUDED BOUNDARY LINE SURVEY. |
| FBC R401.3 SITE DRAINAGE |
| PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH |
| FBC R401.3 DRAINAGE |
| |
| 5. PROVIDE THE FINISHED FLOOR ELEVATION. |
| R403.1.7.3 FOUNDATION ELEVATION. |
| ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| ALL LOCATIONS ON THE SITE. |
| |
| FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION |
| PLAN AND/OR FLOOR PLAN. |
| |
| 6. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND EXT |
| DOORS. |
| FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| |
| 7. PROVIDE A CONNECTOR SCHEDULE FOR SILL PLATE TO FLOOR |
| JOIST AND CEILING JOIST TO STRUCTURE. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 8. ROOF FRAMING |
| |
| 1.PROVIDE DESIGN PRESSURES PER FIGURE R301.2(7) |
| COMPONENT AND CLADDING PRESSURE ZONES |
| R301.2.1.1WIND DESIGN REQUIRED. |
| |
| 2.PROVIDE ROOF SHEATHING FASTENER SCHEDULE |
| TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING |
| SCHEDULE FOR WOOD STRUCTURAL PANELS. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| |
| |
| |
| |