2021-08-13 12:59:37RESTAURANT BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) DRAWING A251 SHOWS THE EGRESS DOOR SIZING
 INCORRECTLY - SHOULD BE (271 X .15) PER FBC 1005.3.2
 2) DRAWING A601 DETAIL 12, 13, 10 AND 18 - HANDRAIL
 EXTENSIONS AT THE BOTTOM OF THE STAIRS SHOULD CONTINUE
 TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM
 RISER. PER FBC 1014.6
 3) PLEASE SHOW ALL HANDRAIL EXTENSIONS AT STAIRS AND
 RAMPS TO RETURN TO A WALL, GUARD OR THE WALKING
 SURFACE. FBC 1014.6
 4) THE HANDRAIL EXTENSIONS FOR STAIRS AND RAMPS WHERE
 THE STAIR OR RAMP DOES NOT CONTINUE SHOULD BE SHOWN TO
 EXTEND OUT FROM THE STAIR OR RAMP NOT END OR TURN
 AROUND THE CORNER PER FBC 1014.6
 5) PLEASE SHOW THE WALL AND CEILING FINISHES FIRE
 CLASSIFICATION PER FBC 803.1
 6) PLEASE SHOW THAT THE REQUIRED FIRE PROTECTION AND
 HOURLY RATINGS FOR THE STEEL JOIST AND COLUMNS EXISTING
 OR NEW TO COMPLY WITH FBC 601 FOR CONSTRUCTION TYPE
 IIIA.
 7) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.2.1
 8) PLEASE PROVIDE A COMPLETE PRODUCT APPROVAL FOR THE
 SWING DOORS.
 9) PRODUCT APPROVAL FOR THE STOREFRONT WINDOWS
 (FL14218) - PLEASE PROVIDE THE FRONT PAGE OF THE
 FLORIDA PRODUCT APPROVAL (THE INSTALLATION INSTRUCTIONS
 HAVE BEEN PROVIDED).
 10) THE ACCESSIBLE BAR COUNTER CANNOT BE PORTABLE AS
 SHOWN ON DRAWING A602 DETAIL 2. (PER THE BUILDING
 OFFICIALS INTERPRETATION) FBC A902
 11) PLEASE SHOW THE KNEE AND TOE CLEARANCE FOR THE
 ACCESSIBLE SEATING AT THE BARS PER FBC 902.2
 12) ACCESSIBLE RESTROOM - PLEASE SHOW THE HEIGHT FROM
 THE FINISHED FLOOR TO THE BOTTOM OF THE "REFLECTIVE
 SURFACE" OF THE MIRROR FBC 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 13) ACCESSIBLE RESTROOM - PLEASE SHOW THE PAPER TOWEL
 DISPENSER OUTLET HEIGHT FROM THE FLOOR TO COMPLY WITH
 FBC 308
 14) ACCESSIBLE RESTROOM - PLEASE SHOW THE REAR TOILET
 GRAB BAR DIMENSIONS FROM THE CENTER OF THE TOILET PER
 FBC 604.5.2
 15) ACCESSIBLE RESTROOM - PLEASE SHOW THE DOOR
 MANEUVERING CLEARANCE TO EXIT THE RESTROOM (18" BESIDE
 THE DOOR) PER FBC 404
 16) PLEASE SHOW THE CLEAR RAMP LANDING LENGTH (5') AT
 THE TOP OF THE REAR ACCESSIBLE RAMP FBC 405.7
 17) PLEASE PROVIDE THE DETAILS (SHOP DRAWINGS) FOR THE
 RAILINGS, ROLLDOWN SHADES, LOUVERED CANOPY SYSTEM ETC.
 - PLEASE LIST ITEMS TO BE DEFERRED ON THE DRAWINGS FBC
 WPB 107.3.4.1
  