2021-08-31 16:07:49 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21070963 |
| |
| NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE. |
| |
| 1- NEW BEDROOM EGRESS WINDOWS DOESN'T SEEM TO COMPLY |
| WITH SEC. R310.2.1 FBC-RESIDENTIAL. TYPICALLY, 5'-0" |
| SINGLE HUNG IMPACT WINDOW DOESN'T PROVIDE THE REQUIRED |
| 24" HEIGHT CLEARANCE. REVISE SIZE OF SINGLE HUNG WINDOW |
| OR PROVIDE MANUFACTURER'S CUT SHEETS SHOWING THAT THE |
| 5'-0" HIGH WINDOW PROVIDE THE REQUIRED. CLEAR HEIGHT. |
| |
| 2- EXISTING BEDROOM LOCATED ON SOUTH SIZE OF PROPOSED |
| HALL. |
| THIS BEDROOM USED TO HAVE AN EGRESS DOOR LEADING TO THE |
| OUTSIDE. THE DOOR WAS REMOVED TO ALLOW FOR THE NEW |
| ADDITION. SPECIFY SIZE AND TYPE OF EXISTING BEDROOM |
| WINDOW TO REMAIN TO VERIFY COMPLIANCE WITH THE EGRESS |
| REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. |
| |
| 3- ADDITION IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT |
| IS SPECIFYING R-30 CLOSED CELL SPRAYED INSULATION UNDER |
| THE METAL ROOF. PROVIDE ICC EVALUATION REPORT FOR THE |
| R-30 INSULATION IN THIS ROOFING SYSTEM TO VERIFY |
| COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. |
| NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN |
| WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. |
| |
| 4- ARCHITECT TO REVISE STUCCO THICKNESS SPECIFIED ON |
| THE BUILDING SECTIONS. NEED TO SPECIFY THE 7/8" MIN. |
| STUCCO THICKNESS AS REQUIRED BY TABLE R702.1(1). |
| FBC-RESIDENTIAL. |
| |
| 5- ARCHITECT NEEDS TO SPECIFY TWO WATER RESISTIVE |
| BARRIERS WHEN STUCCO IS APPLIED TO WOOD AS REQUIRED BY |
| SEC. R703.7.3 FBC-RESIDENTIAL. |
| |
| 6- THERE IS A POOL IN THIS PROPERTY. PROVIDE |
| SPECIFICATIONS SHOWING HOW THE ADDITION WILL COMPLY |
| WITH THE RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. |
| SEC. R4501.17.1.9 FBC-RESIDENTIAL. |
| |
| 7- ENERGY CALCULATIONS SUBMITTED: |
| A)THE ENERGY FORM R405-2020 IS REQUIRED TO BE SIGNED |
| AND DATED BY THE OWNER, ARCHITECT OR OWNER?S LEGALLY |
| DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS |
| REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, |
| PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION. |
| |
| B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| INCLUDING THE BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- |
| ENERGY CONSERVATION. |
| |
| C)REVISE ITEM #2 ON PAGE 1 OF 2. THE ANSWER IS |
| INCORRECT. THE QUESTION IS IF THIS IS A SINGLE FAMILY |
| OR MULTIPLE FAMILY? DETACHED |
| IS NOT THE CORRECT ANSWER. REVISE AS REQUIRED. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| D)REVISE ITEM #11 ON PAGE 1 OF 4. ACCORDING TO PLANS. |
| THE ATTIC IS NOT VENTED. SEE PLANS AND REVISE AS |
| REQUIRED. ALSO, REVISE THE TYPE OF INSULATION ON PAGE 2 |
| OF 4. IT IS FOAM INSULATION NOT BATT INSULATION. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| E)REVISE ROOF MATERIAL ON PAGE 2 OF 4. THERE ARE NO |
| SHINGLES ON THIS ADDITION. IT IS METAL ROOFING. SEE |
| PLANS AND REVISE AS REQUIRED. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| F)REVISE WINDOWS OVERHANG DEPTH AND SEPARATION ON PAGE |
| 3 OF 4 TO MATCH PLANS. SEE PLANS AND REVISE AS |
| REQUIRED. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| G) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| CONSERVATION. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |