Plan Review Notes
Plan Review Notes For Permit 21070715
Permit Number 21070715
Review Stop B
Sequence Number 2
Notes
Date Text
2021-09-20 13:50:50NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21070715
  
 1- OK
  
 2- REVISE ADDRESS ON EACH DRAWING. ADDRESS ASSIGNED TO
 THE MOTHER-IN-LAW STRUCTURE IS 910 WINDSOR AVE NOT 1027
 8TH STREET. REVISE ADDRESS IN ALL DRAWINGS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- OK
  
 4- SHEET 3-3:
 REVISE/CLARIFY THE ROOF SHEATHING NOTE NEXT TO THE ROOF
 PLAN UNDER THE COMPONENT AND CLADDING PRESSURE ZONES
 TABLE. THIS NOTE CONTRADICTS THE NAIL SPACING
 SPECIFICATIONS SHOWN ON THE COMPONENT AND CLADDING
 PRESSURE ZONES TABLE. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 5-OK
  
 6- REVISE ENERGY CALCULATIONS SUBMITTED:
 A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REVISED ENERGY CALCULATIONS WERE NOT SUBMITTED. NEED TO
 SUBMIT REVISED ENERGY CALCULATIONS.
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PROVIDE CORRECT ADDRESS AND OWNER'S NAME, PROVIDE
 NAME OF BUILDER, PERMITTING OFFICE AND JURISDICTION
 NUMBER (THIS JURISDICTION IS 604700).
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REVISED ENERGY CALCULATIONS WERE NOT SUBMITTED. NEED TO
 SUBMIT REVISED ENERGY CALCULATIONS.
  
 C) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT.
 (COORDINATE WITH ITEM #1 ABOVE).
 THIS BUILDING IS FACING CARVER AVE. THESE DOORS ARE
 LOCATED IN THE FRONT AND REAR OF BUILDING. SEE
 SURVEY/SITE PLAN AND FLOOR PLAN AND REVISE AS REQUIRED.
 . THEREFORE, THE CORRECT ORIENTATION IS WEST AND EAST.
 REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REVISED ENERGY CALCULATIONS WERE NOT SUBMITTED. NEED TO
 SUBMIT REVISED ENERGY CALCULATIONS.
  
 D)WINDOWS INFORMATION ON PAGE 3 OF 4 IS INCORRECT.
 (COORDINATE WITH ITEM #1 ABOVE).
 THIS BUILDING IS FACING CARVER AVE. SEE SURVEY/SITE
 PLAN AND FLOOR PLAN AND REVISE AS REQUIRED. THERE ARE
 NO WINDOWS ON THE SOUTH SIDE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REVISED ENERGY CALCULATIONS WERE NOT SUBMITTED. NEED TO
 SUBMIT REVISED ENERGY CALCULATIONS.
  
 E)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 ADDRESS ON EPL FORM SUBMITTED IS FOR 1027 8TH STREET.
 SEE TOP OF EPL FORM SUBMITTED. NEED TO PROVIDE CORRECT
 ADDRESS. REVISE AS REQUIRED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]