Plan Review Notes
Plan Review Notes For Permit 21070278
Permit Number 21070278
Review Stop B
Sequence Number 1
Notes
Date Text
2021-08-11 13:08:18WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21070278
 ADD: 1035 BLANCHE STREET
 CONT: BUILTMORE CONTRACTING, INC.
 TEL: 561-331-1476
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. AUGUST 11, 2021
 ACTION: DENIED
 1) PLEASE NOTE THE BUILDING LOCATED AT 1035 BLANCHE
 ST./ 1615 CLARE AVE. IS LOCATED IN AN (AE) FLOOD ZONE,
 THE BASE FLOOD ELEVATION OR BFE 12.1 NAVD 88. 2020
 FBC-BUILDING CODE SECTION 1612.5 FLOOD HAZARD
 DOCUMENTATION. WEST PALM BEACH MUNI CODE. ARTICLE XVII
 ORDINANCES ARTICLE XVII FLOOD PREVENTION & CONTROL.
 FBC BUILDING 1612 AND CITY OF WPB CODE OF SECTION
 94-546. STRUCTURE IS IN AN "A" FLOOD ZONE. A FLOOD
 ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE REVIEW
 CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE AN
 ADDITIONAL 6 INCHES/ (12 INCHES OF ELEVATION IF PERMIT
 APPLICATION AFTER SEPT. 12/2016,
 AFTER OCT. 11/ 2017 AN ADDITIONAL ONE FOOT OF FREE
 BOARD WILL BE REQUIRED OR (2) FEET ABOVE BASE FLOOD, IN
 THIS CASE THE FINISH FLOOR ELEVATION WOULD BE A MINIMUM
 OF 14.1 FT. NAVD88. AFTER OCT. 11/ 2017 THE BUILDING
 DEPARTMENT WILL HAVE ADOPTED THE NEW FLOOD MAPS IN NAVD
 88 ALL ELEVATIONS NEED TO BE IN NAVD88, NO LONGER USING
 THE NGVD NOMENCLATURE. YOU CAN GO TO THE WEBSITE:
 WWW.NGS.NOAA.GOV/TOOLS/VERTCON/VERTCON.HTML FOR
 CONVERSIONS.
  
 THE PALM BEACH COUNTY PROPERTY APPRAISERS WEBSITE LIST
 THE IMPROVED VALUE (VALUE OF BUILDING) AT $773,336.00
 DOLLARS IN VALUE. THE DECLARED VALUE OF THIS PERMIT
 ALONE IS $450,000.00 DOLLARS IN VALUE.
 THIS IS OVER ONE HALF ($386,668.00) OF THE VALUE OF THE
 BUILDING ON THIS LOT THIS MAKES THIS PERMIT A
 SUBSTANTIAL IMPROVEMENT AND WILL NEED TO COMPLY WITH
 SUBSTANTIAL IMPROVEMENTS. THE OWNERS MAY WANT TO
 CONSIDER DRY FLOOD PROOFING IF THE FINISH FLOOR
 ELEVATION IS LOWER THAN THE ELEVATION 14.1 NAVD 88.
  
 SUBSTANIAL IMPROVEMENT. SECTION 94-546 PROVISIONS FOR
 FLOOD HAZARD REDUCTION. (A)(3) ANY ALTERATION, REPAIR,
 RECONSTRUCTION, OR IMPROVEMENTS TO A PROPERTY WHICH THE
 CUMULATIVE COST FOR ANY FIVE YEAR PERIOD EQUALS OR
 EXCEEDS 50 % OF THE BUILDING VALUE AT THE COMMENCEMENT
 OF THE FIVE YEAR PERIOD SHALL MEET THE REQUIREMENTS OF
 NEW CONSTRUCTION AS CONTAINED IN THIS ARTICLE.
  
 DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE
 REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES
 REQUIRED:
 (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE
 PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR
 HEIGHT. W. P. B. ADMINISTRATIVE CODE 107.3.5.1.1
 BUILDING MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL
 BUILDINGS. ( 8) FLOOD REQUIREMENTS ELEVATIONS,
 ENCLOSURES, FLOOD DAMAGE-RESISTANT MATERIALS.
 (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED. W. P. B.
 ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS 1.2
 FLOOR/ SLAB INSPECTION. IN FLOOD HAZARD AREAS, UPON
 PLACEMENT OF THE LOWEST FLOOR, INCLUDING BASEMENT, AND
 PRIOR TO FURTHER VERTICAL CONSTRUCTION, THE ELEVATION
 CERTIFICATION, REQUIRED IN SECTION 1612.5, SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL.
  
 (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY
 OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANTS A/C PADS OR OTHER SLABS FOR GENERATORS. W.
 P. B. ADMINISTRATIVE CODE 110.3 REQUIRED INSPECTIONS
 (6) FINAL INSPECTION. TO BE MADE AFTER THE BUILDING IS
 COMPLETED AND READY FOR OCCUPANCY. 6.1. LOWEST FLOOR
 ELEVATION. IN FLOOD HAZARD AREAS, AS PART OF THE FINAL
 INSPECTION, A FINAL CERTIFICATION OF THE LOWEST FLOOR
 ELEVATION SHALL BE SUBMITTED TO THE AUTHORITY HAVING
 JURISDICTION.
  
 FEMA NEW FORM AVAILABLE JUNE 13/2016.
 HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM
  
 2) SHEET A202 THE LIFE SAFETY PLAN. BUILDING CODE
 ANALYSIS UNDER THE HEADING OF OCCUPANCY LIST THE
 EXISTING OCCUPANCY AS VACANT. PERMIT 17090272 LIST THIS
 TENANT SPACE AS BUSINESS. WITH THE BLACK CORAL RUM IN
 THE NEXT TENANT SPACE AND A OCCUPANCY OF F-1 & M AND
 THE PROPOSED A2 OCCUPANCY TABLE 508.4 IN THE 2020
 FBC-BUILDING CODE WILL REQUIRE A 2 HOUR FIRE BARRIER
 WALL. SEE SECTION 708.4 CONTINUITY.
  
 3) SHEET A202 UNDER THE HEADING OF EXIT SIGNS SHOWS 3
 EXAMPLES OF DIRECTIONAL EXIT SIGNS, BUT WITHIN THE LIFE
 SAFETY PLAN THERE ARE NO EXIT SIGNS OR EXIT DIRECTIONAL
 SIGNS INDICATING WHICH DOORS LEADING TO THE EXTERIOR OF
 THE BUILDING ARE DESIGNATED EXITS. 2020 FBC-B 1013.1.
  
 4) PLEASE PROVIDE A SITE PLAN AND INDICATE THE DISTANCE
 FROM THE SIDE EXIT TO THE PROPERTY LINE. PLEASE PROVIDE
 IS THERE A SIDEWALK FOR A EXIT? IF THE DISTANCE FROM
 THE SIDEWALL IS LESS THAN 10 FEET TO THE PROPERTY LINE
 PLEASE REVIEW SECTION 1028.4.2 AND 1028.4.1 OF THE 2020
 FBC-BUILDING CODE.
  
 5) SHEET A202 UNDER THE HEADING OF OCCUPANCY LOAD
 INDICATES THE TOTAL DINING ROOM SEATING OF 143
 OCCUPANTS AND 4 ACCESSIBLE SEATS. THE 2020
 FBC-ACCESSIBILITY CODE SECTION 226.1 WHERE DINING
 SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR
 DRINK, AT LEAST 5 PERCENT (143 X 0.05%= 7.15 OR 8
 SEATS) OF THE SEATING SPACES AND STANDING SPACES AT THE
 DINING SURFACES SHALL COMPLY WITH 902.
  
 6) 2020 ACCESS. CODE 226.2 DISPERSION. DINING SURFACES
 AND WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE
 DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING
 DINING SURFACES AND WORK SURFACES.
  
 7) 2020 ACCESS. CODE 206.2.5 206.2.5 RESTAURANTS AND
 CAFETERIAS. IN RESTAURANTS AND CAFETERIAS, AN
 ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL DINING AREAS,
 INCLUDING RAISED OR SUNKEN DINING AREAS, AND OUTDOOR
 DINING AREAS. FOR OUTDOOR SEASONAL SEATING 85 X 0.05=
 4.25 OR 5 ACCESSIBLE SEATS.
  
 8)2020 ACCESS. CODE, MISSING ACCESSIBLE SEATS IN THE
 BAR AREA. 902.1. DINING SURFACES AND WORK SURFACES
 SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1
 GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT LIMITED
 TO, BARS, TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES
 OF WORK SURFACES INCLUDE WRITING SURFACES, STUDY
 CARRELS, STUDENT LABORATORY STATIONS, BABY CHANGING AND
 OTHER TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORKSTATIONS.
  
 8)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 8)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. INCLUDE A
 SECTION OF THE BAR FOR ACCESSIBLE SEATING.
  
 9) SHEET S102 ROOF FRAMING PLAN SHOWS NEW ROOF FRAMING
 MEMBERS, THE EXISTING FRAMING MEMBERS AT 24 INCHES ON
 CENTER BUT THE FRAMING MEMBER SIZE IS NOT GIVEN NOR THE
 SPAN FROM SUPPORT TO SUPPORT. SIZE OF SHEATHING.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. RAFTER
 SPANS PER TABLE 2308.7.2(?)2020 FBC-B.
  
 10) SHEET S102 ROOF FRAMING PLAN NEW ROOF FRAMING PLAN
 SHOWS A NEW HEADER/ WOOD BEAM, BUT THE SPECIES OF WOOD,
 GRADE, & SIZE OF THE BUILT UP BEAM OR WOOD BEAM IS NOT
 GIVEN NOR IS WHERE AND HOW END SPLICES ARE TO BE
 HANDLED. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 11) THERE IS A DISCREPANCY IN THE TYPE OF ROOF TOP CURB
 IN THE PLANS. SHEET A601 SHOWS WOOD FRAMING ROOF SYSTEM
 AND WOOD JOBSITE CURB BUILT. THE M-4 SHEET SHOWS A BAR
 JOIST METAL DECKING AND METAL CURB.
 THE M-4 SHEET ALSO SHOWS ANCHORING OF THE CURB TO THE
 ROOF FRAMING MEMBERS (BAR JOIST) WHERE AS THE WOOD
 BUILT UP CURB ON SHEET A601 DOES NOT INDICATE HOW THE
 CURB IS TO BE ANCHORED TO THE ROOF FRAMING MEMBERS OR
 THE RTU UNIT TO THE CURB. DISCREPANCY IN PLANS AS WELL
 AS ADDITIONAL INFORMATION IS REQUIRED.
 FOR ALL ROOF TOP EQUIPMENT, CURBS, FANS OR A/C STANDS,
 AND OR VENTS, DETAILED ATTACHMENT TO THE ROOF FRAMING &
 DECK AS WELL AS FROM THE CURB OR ROOF STAND TO THE
 EQUIPMENT ABOVE.
  
 2020 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
  
 12) 2020 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, CURBS, ROOF TOP VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 13) NO WIND DESIGN NOR PRESSURES ARE GIVEN FOR THE NEW
 OPENINGS IN THE EXTERIOR WALL. 2020 FBC-B 1603.1.4 WIND
 DESIGN DATA.
  
 14) WELDED OR BOLTED CONNECTIONS
 THIS BUILDING CONTAINS EITHER BOLTED AND OR WELDED
 CONNECTIONS. THE CONTRACTOR IS REQUIRED TO PROVIDE WELD
 PROCEDURE SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION FOR FIELD WIELDING, ON
 THE JOB-SITE WIELDING. THIRD PARTY CERTIFICATION WILL
 BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 15) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  