Date Text
2021-08-19 14:36:191) SUBMIT DETAILS OF THE GREASE INTERCEPTOR. THE
 INTERCEPTOR SHALL COMPLY WITH CITY STANDARD DRAWING
 GS-7 OR GS 7.1. PLEASE CONTACT THE CITY OF WEST PALM
 BEACH ENGINEERING DEPT. AT 561-494-1079 OR 561-835-7423
 FOR A COPY OF THE STANDARD DRAWING.
 2) THE SIZING OF THE GREASE INTERCEPTOR SHALL COMPLY
 WITH FBC-PLUMBING SEC.1003.3.5. THE INTERCEPTOR SHALL
 BE SIZED BASED ON PDI G101 OR RULE 64E-6, FLORIDA
 ADMINISTRATIVE CODE.
 3) SUBMIT A SITE PLAN OR CIVIL PLAN SHOWING THE
 LOCATION OF THE GREASE INTERCEPTOR ON THE PARCEL. WPB
 AMEND. TO FBC SEC. 107.2.1, 107.3.5.1.3.
 4) THE MAXIMUM SIZE OF ANY SINGLE TANK FOR A GREASE
 INTERCEPTOR SHALL BE 1250 GALLONS PER CITY STANDARD
 DRAWING GS-7.
 5) CLEAR WATER WASTE SHALL NOT BE DISCHARGED TO THE
 GREASE WASTE SYSTEM PER FBC-PLUMBING SEC.1003.2.
 6) HAND SINKS SHALL NOT DISCHARGE TO THE GREASE WASTE
 SYSTEM PER FBC-PLUMBING SEC.1003.2.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  