2021-07-03 15:20:45 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT:21061027 |
| ADD: 2400 PRESIDENTIAL WAY # 503 |
| CONT: WINDOW & DOOR DESIGN CENTER |
| TEL: 561-348-4805 |
| E-MAIL: PERMITS@ AANDJPERMITS.COM |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: SAT. JULY 03RD/ 2021 |
| ACTION: DENIED |
| 1) THE FLOOR PLAN LAYOUT INDICATES THE WORK TO BE |
| PREFORMED UNDER THIS PERMIT IS A CORNER UNIT OF A |
| HIGHRISE BUILDING. THE WIND LOAD CHART UNDER NOTES |
| STATES WHAT IS CONSIDERED AN END ZONE 10% OF THE LEAST |
| HORIZONTAL DISTANCE OF THE BUILDING OR 40% OF THE MRH, |
| BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DISTANCE |
| OR 3 FT. THE CONTRACTOR HAS NOT IDENTIFIED WHAT THE |
| LEAST HORIZONTAL DISTANCE IS FOR THE BUILDING. THE |
| BUILDING HEIGHT IS APPROXIMATELY 180 FT, MRH. X 0.40= |
| 72 FEET. THIS WOULD PUT ALL OPENINGS IN WIND ZONE 5. |
| |
| 2) SUBMITTED WIND DESIGN TABLE IS FOR EXPOSURE D. THE |
| CORRECT TABLE WOULD BE EXPOSURE C, THIS WOULD DROP BOTH |
| THE POSITIVE AND NEGATIVE PRESSURES. THE SILL HEIGHT |
| MAYBE ABLE TO BE DROPPED TO 3 ? INCHES (POSITIVE |
| PRESSURES FOR SILLS). |
| |
| 3) THE SUBMITTED FLOOR PLAN NEEDS THE CONTRACTOR TO |
| TAKE OWNERSHIP OF THE PLAN. CERTIFICATION BY |
| CONTRACTOR. 107.3.4.3. THE CONTRACTOR (QUALIFIER) THAT |
| CREATED / DREW THE SET OF PLANS WILL NEED TO IDENTIFY |
| THEMSELVES AS THE AUTHOR OF THE PLANS. PLEASE PRINT |
| YOUR NAME, SIGN YOUR NAME AND LICENSE NUMBER FOR THE |
| TRADE YOU ARE LICENSED IN AND PLANS DRAWN. |
| |
| 4) THE WIND LOAD CHARTS SUBMITTED APPEAR TO BE PAPER |
| AND UPLOADED. THERE IS NO SIGNATURE NOR SEAL ON THE |
| WIND LOAD CHART. FLORIDA ADMINISTRATIVE CODE |
| 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER, |
| SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE |
| OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON |
| DIGITALLY SIGNED AND SEALED ENGINEERING PLANS, |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING |
| ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| |
| 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 |
| IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ |
| RETIRED. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |