Date |
Text |
2021-07-19 13:46:05 | PLAN REVIEW BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/SFP306 |
| INSPECTOR BN4338 |
| BUILDING OFFICIAL BU1635 |
| ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| DEVELOPMENT SERVICES DEPARTMENT |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| 2017 NEC |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE SPECIFICATIONS FOR MAIN DRAINS PER FBC |
| 454.1.6.;5.10.2. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 2. REF. PLAN PAGE P1.0 FOR THE FOLLOWING: |
| CODE REFERENCES 454.1.3.1.2/.6 AND .9 ARE NOT PER |
| CURRENT 2020 FBC. PLEASE UPDATE THESE CODE REFERENCES. |
| |
| 3. PROVIDE SPECIFICATIONS THAT COMPLY WITH THE 2020 FBC |
| FOR THE CHAIR LIFTS. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 4. REF. PLAN PAGE P1.0 FOR THE FOLLWOING: |
| PROVIDE STATEMENT THAT THE CHAIR LIFTS SHALL COMPLY |
| WITH THE 2020 FBC SEC. 1009.2 THRU 1009.9. |
| |
| 5. REF. PLAN PAGE P1.1 FOR THE FOLLWING: |
| REF. PLAN PAGE P1.1 FOR THE FOLLWING: |
| P1.1 & P1.2: A COMPLETE REVIEW OF THE REQUIRED PLUMBING |
| FIXTURE COUNTS FOR THE DAY POOL AND SALT SPA CANNOT BE |
| COMPLETED AT THIS TIME DUE TO A LACK OF INFORMATION ON |
| THE PLANS- THE NUMBER OF PLUMBING FIXTURES HAS NOT BEEN |
| CALCULATED BY THE SQUARE FOOTAGE AREAS OF THE POOL AND |
| SPA AS REQUIRED BY TABLE 454.16.1 FBC B. BECAUSE |
| RESTROOM FACILITIES FOR THE DAY POOL AND SALT SPA ARE |
| BEING PROVIDED BY THE HOTEL BUILDING, PLEASE REVIEW THE |
| EXCEPTION UNDER SECTION 454.1.6.1.1 FBC B AND PROVIDE: |
| A) THE FIXTURE REQUIREMENT FOR THE BUILDING. IF IT |
| EXCEEDS THE REQUIREMENT IN TABLE 454.1.6.1 THEN THE |
| BUILDING REQUIREMENT SHALL REGULATE THE FIXTURE COUNT, |
| OTHERWISE THE FIXTURE COUNT SHALL BE BASED ON THE |
| REQUIREMENT FOR THE POOL. UNDER NO CIRCUMSTANCES SHALL |
| THE FIXTURE COUNTS BE CUMULATIVE. B) WOMEN'S RESTROOMS |
| SHALL HAVE A RATIO OF THREE TO TWO WATER CLOSETS |
| PROVIDED FOR WOMEN AS THE COMBINED TOTAL OF WATER |
| CLOSETS AND URINALS PROVIDED FOR MEN. LAVATORY COUNTS |
| SHALL BE EQUAL. |
| A COMPLETE ACCESSIBILITY REVIEW CANNOT BE PERFORMED AT |
| THIS TIME. PROVIDE COMPLETE ADA SPECIFICATIONS FOR |
| SANITARY FACILITIES PER FBC ACCESS. CHPT. 6. |
| |
| 6. REF. PLAN PAGE P1.2 FOR THE FOLLOWING: |
| IDENTIFY LOCATION OF THE DAY SPA AND SALT SPA. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 7. REF. PLAN PAGE P1.2 FOR THE FOLLOWING: |
| DECK DRAINS APPEAR TO BE MISSING AT THE ADULT POOL PER |
| FBC 454.1.3.1.2. |
| |
| 8. GUTTER SPECIFICATIONS: |
| GUTTER SPECS ON PG. AP2.0 SPECIFIES A PENTAIR MODEL |
| GUTTER. DETAIL ON PG. AP2.2 SHOWS A HAYWARD MODEL OF |
| GUTTER. |
| PLEASE CLARIFY. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| |
| |