2021-06-09 10:32:52OFFICE RENO
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE ACCESSIBLE RESTROOM MIRROR MAXIMUM
 HEIGHT FROM THE FINISHED FLOOR TO THE REFLECTING
 SURFACE TO COMPLY WITH FBC A603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 2) PLEASE SHOW THE DOOR MANEUVERING CLEARANCE FROM
 INSIDE THE RESTROOM (102) TO COMPLY WITH FBC 404.2.4
 3) PLEASE SHOW THE ACCESSIBLE "BUSINESS LOUNGE" DINING
 AREA TO COMPLY WITH FBC A902.2 CLEAR FLOOR OR GROUND
 SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A
 FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. - FBC
 A902.3 HEIGHT.
 THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE
 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
 4) PLEASE SHOW THE INTERIOR FLOOR FINISHES (CARPET) TO
 COMPLY WITH FBC 804.4