2021-06-15 16:16:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
  
 PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED
 WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE
 NUMBER IN ACCORDANCE WITH WPB FBC 107.3.4.3, A PAPER
 PLAN WITH WET SIGNATURE SHALL BE PROVIDED TO THE
 BUILDING DEPARTMENT FOR HARD RECORD FILE PRIOR TO
 ISSUANCE OF A PERMIT.
  
 PLUMBING COMMENTS: DENIED
  
 PER WPB FBC 104.1, A PLUMBING SUB-PERMIT APPLICATION
 SHALL BE SUBMITTED FOR THIS PROJECT BY A LICENSED
 PLUMBING CONTRACTOR.
  
 1.AS THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, A SEPARATE PLUMBING
 PLAN IN ACCORDANCE WITH WPB FBC 107.3.4.3 SHALL BEAR
 THE PRINTED NAME, THE SIGNATURE AND THE CERTIFICATION
 NUMBER OF THE DESIGNER WHO SHALL BE A CONTRACTOR
 LICENSED IN THE PLUMBING TRADE.
  
 A.PER WPB FBC 107.2.1, PROVIDE A KITCHEN FLOOR PLAN
 NAMED PLUMBING PLAN: PROVIDE THE FOLLOWING:
 1) INDICATE ACTUAL PLUMBING SCOPE OF WORK I.E. REPLACE
 EXISTING SINK WITH NEW, MAKE PLUMBING CONNECTIONS TO
 SINK, DISHWASHER AND REFRIGERATOR ICE MAKER.
 2 )PROVIDE NOTE, "ALL WORK TO COMPLY WITH FLORIDA
 PLUMBING CODE 2020 7TH EDITION."
 3) PROVIDE NOTE, "PROVIDE WATER HAMMER ARRESTORS PER
 FLORIDA PLUMBING CODE 604.9"
 4) PROVIDE NOTE, "CONNECT DISHWASHER WASTE DIRECTLY TO
 A WYE BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN
 SINK, DIRECTLY TO THE DISHWASHER CONNECTION OF A FOOD
 WASTE DISPOSER, OR THROUGH AN AIR BREAK TO A STANDPIPE.
 THE WASTE LINE OF A RESIDENTIAL DISHWASHER SHALL RISE
 AND BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK
 RIM OR COUNTER TOP PER FLORIDA PLUMBING CODE 604.9"
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21060265 1701 S FLAGLER DR # 1208


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved