2021-06-16 09:05:52THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. THIS DOCUMENT HAS
 BEEN REVISED. PLEASE EMAIL STAFF AT [email protected]
 TO REQUEST THE EXAMPLE. AT MINIMUM, STAFF NEEDS TO KNOW
 THE EXISTING WINDOWS AND THE PROPOSED WINDOWS -
 MATERIAL, EXTERIOR FRAME COLOR, GLASS GLAZING, LITE
 PATTERN, MUNTIN PROFILE AND MULLION WIDTH. A PHOTO OF
 EACH ELEVATION WITH EACH WINDOW MARKED AND CLEARLY
 VISIBLE. IF SHUTTERS OR SIMILAR VISUAL OBSTRUCTION
 EXISTS, MULTIPLE PHOTOS MAY BE REQUIRED. INCLUDE THE
 ORDER DETAIL QUOTE/DETAILED CUSTOMER PROPOSAL.
 2. REVISE WINDOWS TO HAVE AN ANODIZED FINISH. CGI?S
 LOW-PROFILE MUNTIN PROFILE WILL BE REQUIRED ON THE
 EXTERIOR TO REPLICATE THE EXISTING AWNING AND FIXED
 WINDOWS.
 3. IF THE EXISTING AWNING WINDOW IS A 4-PANEL AWNING
 WINDOW, REVISE TO AN AWNING WINDOW, CASEMENT WITH
 HORIZONTAL 4-LITES, OR A HORIZONTAL 2/2 SINGLE-HUNG.
 4. IF THE EXISTING AWNING WINDOW IS A 3-PANEL AWNING
 WINDOW, REVISE TO AN AWNING WINDOW, CASEMENT WITH
 HORIZONTAL 3-LITES, OR A HORIZONTAL 2/1 ORIEL
 SINGLE-HUNG WINDOW.
 5. IF THE EXISTING AWNING WINDOW IS A 2-PANEL AWNING
 WINDOW, REVISE TO AN AWNING WINDOW, CASEMENT WITH
 HORIZONTAL 2-LITES, OR A 1/1 SINGLE-HUNG WINDOW.
 6. WINDOW #24, THE CENTER SECOND FLOOR WINDOW MAY NEED
 TO BE RETAINED IF IT CANNOT BE ACCURATELY RECREATED
 WITH A REPLACEMENT WINDOW.
 7. ADDITIONAL INFORMATION MAY CHANGE REVISION
 REQUIREMENTS.
  
  
 PROPOSED CONDITIONS, SUBJECT TO CHANGE. CONFIRM THAT
 THE PROPOSED PRODUCT(S) WILL COMPLY WITH THESE
 CONDITIONS.
 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND
 MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL
 WINDOWS.
 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED
 WITH A MULLION OF MATCHING WIDTH AND PLACEMENT.
 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR.
 ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR
 WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS
 MAY BE USED ON NON-STREET FACING BATHROOMS ONLY.
  
 AARON BORNGRABER, AICP
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES