Date |
Text |
2021-06-24 13:45:47 | PLAN REVIEW / NFIP |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER BUILDING - PX3169 |
| PLANS EXAMINER 1&2 FAMILY - SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| CODES IN EFFECT: |
| 2017 FLORIDA BUILDING CODE, 5TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| CITY ORDINANCE NO. 4658-16 |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| NOTICE: BUILDING UNDER CONSTRUCTION ELEVATION |
| CERTIFICATES (EC) FOR MAIN HOUSE AND CABANA |
| |
| CABANA EC - SEE SIGNATURE REVIEW |
| |
| MAIN HOUSE - |
| |
| 1. SECTION A8 (D) - INDICATES ENGINEERED FLOOD |
| OPENINGS. PLEASE CORRECT. |
| |
| 2. SECTION A9 (A) - SF OF GARAGE IS 1047 SF. PLAN PAGE |
| A-1 SHOWS SF OF GARAGE AS 860 SF. REVISION TO PLAN |
| REQUIRED. |
| |
| 3. SECTION A9 (B) - ENTER NUMBER OF FLOOD OPENINGS. |
| |
| 4. A9 (C) - ENTER NET AREA OF FLOOD OPENINGS. |
| NOTE: PLAN PAGE A-1 AND SP-1 SHOW 5 VENTS INSTALLED ON |
| ONE WALL. VENTS SHALL BE INSTALLED ON ADJACENT WALLS |
| PER FEMA TECH BULLITEN #1. |
| |
| 5. SECTION B 1 - NFIP COMMUNITY NAME AND NUMBER STATES |
| TOWN OF PALM BEACH 120220. B1 SHOULD STATE - WEST PALM |
| BEACH, CITY OF; COMMUNITY NUMBER IS 120229. PLEASE |
| CORRECT. |
| |
| 6. SECTION C 2 (B) - MISSING DATA. |
| |
| 7. SECTION C 2 (E) - MISSING DATA. |
| |
| 8. SECTION D - COMMENTS - INCLUDE TYPE OF EQUIPMENT AND |
| LOCATION PER C 2 (E). |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| |