Date |
Text |
2021-06-23 16:20:34 | PLAN REVIEW BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 |
| INSPECTOR BN4338 |
| BUILDING OFFICIAL BU1635 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| 2017 NEC |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. AN 8 X 16 ENGINEERED FLOOD VENT IS PROPOSED TO BE |
| INSTALLED IN THE GARAGE DOOR. SUBMIT THE FLORIDA |
| PRODUCT APPROVALS FOR A GARAGE DOOR WITH THE PROPOSED |
| FLOOD VENT INSTALLED. |
| FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| |
| 2. SECTION C2 D) OF ELEVATION CERTIFICATE SHOWS TOP OF |
| GARAGE FLOOR AT 5.3 FT NAVD. PLAN PAGE S-100 IN MASTER |
| PERMIT 20090239 SHOWS TOP OF GARAGE FLOOR AT 8.0 FT |
| NAVD. RES REV 20090239 WAS SUBMITTED TO LOWER THE |
| GARAGE FLOOR. THIS REVISION HAS NOT BEEN APPROVED. NO |
| DRAWINGS HAVE BEEN SUBMITTED FOR REVIEW. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| NOTE IN FINAL BLDG REVIEW FOR MASTER PERMIT 20090239, |
| PER EOR ON 2/01/21: |
| |
| REVIEWED WITH DOR, PATRICK WITH DAILY AND JANSSEN. |
| BLDG. REVIEW WILL BE APPROVED WITH THE FOLLOWING |
| PROVISOS: |
| |
| 1. NEW PLAN SHEET A-1.01 WILL BE SUBMITTED WITH NEW |
| FLOOD VENT CONFIGURATIONS. 2-8X16 VENTS INSTALLED ON |
| WEST WALL WITH BOTTOM OF VENTS AT FINISHED FLOOR |
| ELEVATION OF 8.0 FEET NAVD. NOTE STATING TOP OF VENTS |
| ARE BELOW DFE AND THE 1-8X16 VENT INSTALLED IN THE OHD |
| WILL REMAIN. NOTES IDENTIFYING VENTS WILL BE AMMENDED. |
| |
| 2. SP-1.01 WILL REMAIN WITH RED LINE OF DINING AREA FF |
| ELEAVATION OF 9.0 FEET CHANGED TO 9.5 FEET NAVD AND |
| LETTER ADDRESSING FINISHED GRADE OF 7.6 FEET NAVD AT |
| WEST ELEVATION. LETTER ADDRESSES SITE WALL PERMIT |
| 20070578 AND REVISION 20070578 ISSUED UNDER PREVIOUS |
| ADDRESS OF 101 SANTA LUCIA DR. LETTER WILL PROVIDE TOP |
| OF WALL ELEVATION TO BE 8.0 FEET NAVD. |
| |
| 3. SITE DRAINAGE PLAN TO BE SUBMITTED FOR REVIEW. |
| |
| 4. UNDER CONSTRUCTION EC AND FINISHED CONSTRUCTION EC |
| REQUIRED. - SEE PROVISO'S UNDER MASTER PERMIT 20090239 |
| - NFIP REVIEW. |
| CT |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| |