2021-06-19 09:11:38PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. REF. PAGE S0.3. , COMPONENTS AND CLADDING - DESIGN
 IS BASED ON ASCE 7-10. THIS DOCUMENT HAS EXPIRED.
 PLEASE USE THE 2020 FBC RES AND ASCE 7-16 FOR YOUR
 DESIGN.
 REF: PAGE A-001. GENERAL NOTES: OCCUPANCY GROUP STAES
 THIS IS AN ALTERATION LEVEL 3. THIS IS A NEW SFR.
 PLEASE CORRECT.
  
 PROVIDE PROJECT DESIGN PARAMETERS:
  
 2020 FBC RESIDENTIAL; ASCE 7-16; 2017 NEC
 CLASSIFICATION OF WORK: NEW SFR
 CONSTRUCTION TYPE: VB
 OCCUPANCY: R3
 EXPOSURE CLASSIFICATION: (C OR D)
 RISK CATEGORY: II
 MEAN ROOF HEIGHT: ( ) 2 STORY
  
 2. PROVIDE ROOF SHEATHING FASTENER SCHEDULE BASED ON
 DESIGN WIND LOADS FOR ZONES 1, 2 AND 3.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 3. PROVIDE A SITE DRAINAGE PLAN.
 SITE PLAN/DRAINAGE PLAN/SURVEY
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
  
 4.REF: SOILS REPORT: THE SOILS REPORT SUBMITTED FOR
 REVIEW IS FOR A ONE STORY STRUCTURE. THIS PROJECT IS A
 2 STORY STRUCTURE. THE SOILS REPORT ALSO STATES THAT
 ADDITIONAL BORINGS ARE REQUIRED FOR THE REAR OF THE
 PROPERTY DUE TO LACK OF ACCESS. SUBMIT A CORRECTED
 SOILS REPORT.
 1803.2 INVESTIGATIONS REQUIRED.
 GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN
 ACCORDANCE WITH SECTIONS 1803.3 THROUGH 1803.5.
  
 5. PROVIDE AN ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 6. PRODUCT APPROVALS SUBMITTED FOR REVIEW FOR THE
 WINDOWS AND DOORS INCLUDE PAGE 1 ONLY. SUBMIT A
 COMPLETE SET OF PRODUCT APPROVALS INCLUDING THE
 INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 7. PROVIDE A WINDOW AND DOOR SCHEDULE. PROVIDE THE
 DESIGN PRESSURES AND ROUGH OPENINGS OF EACH WINDOW AND
 DOOR. IDENTIFY THE OPENINGS ON THE PLANS.
  
 1. LOCATION REFERENCE TO OPENING NUMBER ON PLAN.
 2. WINDOW/DOOR TYPE
 3. ROUGH OPENING WXH (AREA SF)
 4. DESIGN PRESSURE OF OPENING (TABLE R301.1.(2) OR ASCE
 7-16
 5. NOA OR FL NUMBER
 6. MAX DESIGN PRESSURE FROM NOA OR FL
 7. IDENTIFY EGRESS OPENINGS
  
 7. PROVIDE SECTIONAL VIEW OF EXTERIOR WALL/FOUNDATION
 AND ROOF. INCLUDE PROPOSED CONNECTORS AND CEILING AND
 WALL INSULATION R-VALUE
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  