2021-09-14 13:09:32 | 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 21050792 |
| ADD: 400 N. FLAGLER DR. # 1705 |
| CONT: LARSEN BUILDERS CORP |
| TEL: 561-403-5851 |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: TUES. SEPT. 14TH/ 2021 |
| ACTION: DENIED |
| |
| ***** 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) |
| ***** |
| WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? |
| DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
| |
| |
| 1) 2ND REQUEST. SHEET A-1.0 FLORIDA ADMINISTRATIVE CODE |
| 61G15-23.005 (3)(C) A DOCUMENT IN THE FILE FOLDER, |
| SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE |
| OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON |
| DIGITALLY SIGNED AND SEALED ENGINEERING PLANS, |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| |
| 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING |
| ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| |
| 2) THE FLOOR PLAN INDICATES IN THE MASTER BEDROOM, |
| BEDROOM 1 & 2 ALL ARE TO RECEIVE NEW MARBLE FLOORS. |
| FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, |
| STONE, MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE |
| HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO |
| THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS |
| LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH |
| CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: |
| PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR |
| TYPE II BUILDINGS SHOWING COMPLIANCE WITH: |
| |
| 2A) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE |
| SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS |
| OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. |
| |
| 2B) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. |
| WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| E 90. |
| |
| 2C) 2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1. |
| EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED |
| FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE |
| SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT |
| MORE THAN 200. |
| |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| 3) NO WIND DESIGN PROVIDED 2ND REVIEW. |
| |
| 1ST ROUND OF COMMENTS. THE SUBMITTED WIND DESIGN BY |
| MANUEL SIQUES P. E. IS NOT SIGNED NOR SEALED. |
| 361G15-23.002(2)(B) FL. ADMIN. CODE. A COVER SHEET WITH |
| LISTED PAGES OR INDEX SHEET FOR ENGINEERING |
| SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE |
| SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION & |
| PREPARATION OF EACH SECTION OF THE ENGINEERING |
| SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER |
| SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER |
| THE COVER SHEET OR INDEX SHEET. . |
| FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A |
| DOCUMENT IN THE FILE FOLDER, SCANNED, FACSIMILE, |
| DIGITALLY CREATED OR COPIED IMAGE OF THE LICENSEE'S |
| SIGNATURE SHALL NOT BE USED ON DIGITALLY SIGNED AND |
| SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR |
| OTHER DOCUMENTS. |
| 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING |
| ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.) |
| |
| 4) 2ND ROUND OF COMMENTS. COULD NOT FIND THE COMPUTER |
| GENERATED CALCULATIONS. |
| |
| 1ST ROUND COMMENTS. WITHIN THE COMPUTER-GENERATED |
| PROGRAM THE INPUT OF THE EAVE HEIGHT IS GIVEN AT 185 |
| FEET. PLEASE NOTE THE 1ST FLOOR AREAS ARE NOT THE |
| NORMAL 8-FOOT-HIGH CEILINGS, PLUS THIS BUILDING BEING |
| 23 STORIES TALL THE EAVE HEIGHT OF 185 /23 = 8.043 FEET |
| TALL OR 8 FEET -0 INCH, NO ROOM FOR THE FLOOR SLABS. I |
| BELIEVE THE HEIGHT CALCULATION IS OFF THAT WILL AFFECT |
| THE RESULT OF THE +/ - PRESSURES SHOWN IN THE PROGRAM |
| AND FLOOR PLAN. 107.2.1.2. ADDITIONAL INFORMATION IS |
| REQUIRED. WE USUALLY SEE A HEIGHT OF 220 FT. FOR THIS |
| BUILDING. |
| |
| 5) 2ND ROUND OF COMMENTS. PLEASE, PLEASE SUBMIT THE |
| PRODUCT APPROVAL COVERSHEET AND TECHNICAL DRAWINGS IN |
| THE SAME FILE FOLDER DO NOT SPLIT THEM UP INTO |
| DIFFERENT FILE FOLDERS. IF THEY ARE NOT SUBMITTED |
| TOGETHER FLORIDA APPROVALS DO NOT ALWAYS HAVE A |
| TRACKING NUMBER ON THE TECHNICAL SHEETS. 107.2.1.2. |
| ADDITIONAL INFORMATION REQUIRED. 107.2.1.3. QUALITY OF |
| PLANS. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| DEPARTMENT POLICY OTHER STANDARDS FOR THE PLANS AND |
| SPECIFICATIONS IN ORDER TO PROVIDE CONFORMITY TO ITS |
| RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH |
| THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR |
| OTHER ITEMS RELATED TO RECORD MANAGEMENT. ELECTRONIC |
| MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS |
| OF FLORIDA STATUTES. |
| |
| 6) 2ND ROUND OF COMMENTS. IDENTIFY GLAZING/ MULLIONS. |
| PLEASE IDENTIFY IN THE PRODUCT APPROVAL BEFORE |
| SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION |
| TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH |
| GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, |
| TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED |
| OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND |
| ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B |
| 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE |
| INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S |
| INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE |
| PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED |
| BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. |
| |
| 7) 2ND ROUND OF COMMENTS. W. P. B. 107.3.4. PRODUCT |
| APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY |
| FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE |
| REVIEWED AND APPROVED IN WRITING (SHOP DRAWING STAMP OF |
| APPROVAL) BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| 8) 2ND ROUND OF COMMENTS. THE FLOOR PLAN IN THE |
| BATHROOMS STATES NEW FIXTURES. IN BOTH THE GUEST SHOWER |
| AND MASTER BATH ARE THE SHOWER WALLS AND SHOWER FLOORS |
| BEING REPLACED, THE PLANS ARE NOT CLEAR ON THIS |
| SUBJECT. IF SO PLEASE SHOW COMPLIANCE WITH: 2020 FBC-B |
| 2509.2 BASE FOR TILE. MATERIALS USED AS A BASE FOR WALL |
| TILE IN TUB AND SHOWER AREAS AND WALLS AND CEILING |
| PANELS IN SHOWER AREAS SHALL BE OF MATERIALS LISTED IN |
| TABLE 2509.2 AND INSTALLED IN ACCORDANCE WITH |
| MANUFACTURER?S RECOMMENDATIONS. WATER RESISTANT GYPSUM |
| BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER |
| CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE |
| WITH GA-216 OR ASTM C840 AND THE MANUFACTURE?S |
| RECOMMENDATIONS. |
| |
| 9) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 |
| IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ |
| RETIRED. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |