2021-05-25 10:55:27WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21050160
 ADD: 3915 S. FLAGLER DR. # 310
 CONT: VERITAS DEVELOPMENT LLC
 TEL: 561-346-4330
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 25TH/ 2021
 ACTION: DENIED
 1) PLEASE PROVIDE A NOTARIZED LETTER FROM EITHER THE
 CONDOMINIUM BOARD ASSOCIATION OR THE MANAGEMENT COMPANY
 APPROVING CHANGES TO THE EXTERIOR OF THE BUILDING
 (COMMON AREAS) AS PER FL. STATUTE 718 FOR CONDOMINIUMS.
  
 2) THERE WAS NO FLOOR PLAN SUBMITTED SHOWING THE SIZE
 OF THE BALCONY TO BE ENCLOSED. THE SLIDING GLASS DOORS
 LEADING FROM THE INTERIOR OF THE CONDO TO THE BALCONY,
 ARE THEY GOING TO BE REMOVED?
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION: 107.3.5 MINIMUM PLAN
 REVIEW CRITERIA FOR BUILDINGS AND OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
 MISSING CODE DATA:
 FLOOR PLAN OF BALCONY.
 WIND DESIGN CRITERIA.
  
 3) MISSING FROM SUBMITTAL. 2020 FBC-B 1603.1.4 WIND
 DESIGN DATA. THE FOLLOWING INFORMATION RELATED TO WIND
 LOADS SHALL BE SHOWN, REGARDLESS OF WHETHER WIND LOADS
 GOVERN THE DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM
 OF THE STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 3.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED
 CONVERSION VULT TO VASD.
  
 4) 2020 FBC-B SECTION THE ARCHITECT OR PROFESSIONAL
 ENGINEER OF RECORD SHALL BE REQUIRED TO SPECIFY THE
 DESIGN WIND PRESSURES, DETERMINED IN ACCORDANCE WITH
 CHAPTER 16 FOR ALL OPERABLE AND FIXED WINDOWS GLAZING.
  
 5) THE ELEVATION VIEW (BALCONY DRAWING DOES NOT
 INDICATE THE SIZE OF THE VERTICAL AND HORIZONTAL
 MULLIONS. AS DRAWN BOTH THE VERTICAL AND HORIZONTAL
 MULLIONS HAVE A JOINT IN THE CENTER WHERE ALL MEET,
 THIS MAKES FOR A EXTREMELY WEAK POINT THAT IS
 INCORRECT. THE SHORTER SPAN OF EITHER THE VERTICAL OR
 HORIZONTAL FRAMING MEMBER WOULD BE THE MULLION THAT
 WOULD GO FULL LENGTH. EITHER FLOOR TO CEILING OR
 SUPPOSED WALL TO WALL. THE ELEVATION VIEW SUBMITTED
 DOES NOT INDICATE WHAT THE END OF THE WINDOWS AND
 HORIZONTAL MULLIONS FASTEN TO? THIS NEW WALL IS
 BECOMING PART OF THE MWFRS (MAIN WIND FORCE RESISTING
 SYSTEM).
  
 6) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved