2021-05-06 15:49:35FINAL ELEVATION CERTIFICATE REVIEW COMMENTS:
 SUBMITTAL #21041684
  
 1- REVISE INFORMATION ENTERED IN SECTION C2:
 (A) THERE IS NO INFORMATION IN THE SURVEY FOR THE
 ELEVATION AT THE LOADING AREA ON THE NORTH SIDE OF THE
 BUILDING. ACCORDING TO PLANS, THE ELEVATION AT THE
 ENTRANCE OF THE LOADING AREA IS LOWER THAN THE REST OF
 THE FLOOR. THIS LOOKS LIKE THE TOP OF BOTTOM FLOOR.
 REVISE AS REQUIRED.
 PROVIDE FINAL SURVEY SHOWING ELEVATIONS IN THE LOADING
 AREA. (INCLUDE THE FIRE PUMP ROOM, TRASH ROOM, DOMESTIC
 PUMP ROOM).
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 (B) COORDINATE WITH ITEM #1 ABOVE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 (C)OK.
  
 (D)ACCORDING TO FINAL SURVEY SUBMITTED IT LOOKS LIKE
 THE TOP OF ATTACHED GARAGE ELEVATION IS TAKEN AT A
 MIDPOINT OF THE GARAGE RAMP. THE LOWEST ELEVATION OF
 THE GARAGE IS AT THE ENTRANCE OF THE GARAGE. REVISE AS
 REQUIRED.
 ALSO, REVISE ELEVATION 12.4. ACCORDING TO SURVEY THIS
 ELEVATION IS 12.38. THE ELEVATION NEEDS TO BE ENTERED
 TO THE NEAREST TENTH OF A FOOT AS REQUIRED BY ITEM C2
 OF FEMA ELEVATION CERTIFICATE INSTRUCTIONS. THEREFORE,
 THE CORRECT ROUNDING WILL BE 12.0 NOT 12.4.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 (E)OK.
  
 (F)SURVEY SUBMITTED DOESN'T SHOW THE LOWEST ADJACENT
 GRADE NEXT TO THE BUILDING. UNABLE TO VERIFY. PROVIDE
 SURVEY WITH INFORMATION.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 (G)SURVEY SUBMITTED DOESN'T SHOW THE HIGHEST ADJACENT
 GRADE NEXT TO THE BUILDING. UNABLE TO VERIFY. PROVIDE
 SURVEY WITH INFORMATION.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 (H) SURVEY SUBMITTED DOESN'T SHOW ELEVATION OF DECK OR
 STAIRS. UNABLE TO VERIFY. PROVIDE SURVEY WITH
 INFORMATION.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 2- PROVIDE PHOTOS SHOWING THE VENTS SPECIFIED ON ITEM
 A9(B).
 NOTE: COORDINATE WITH VENTS SHOWN ON SHEET A.2.1 AND
 DETAILS 4 AND 8 ON SHEET A-8.1.1. THERE IS A VENT
 INSIDE THE GARAGE CONNECTING TO THE OUTSIDE WALL. THE
 OTHER VENT CONSIDERED BY THE ARCHITECT OF RECORD IS THE
 ENTRANCE TO THE GARAGE. SHOW ALL VENTS. SEE ITEM A6
 FEMA ELEVATION CERTIFICATE INSTRUCTIONS.
 ALSO, ALL PHOTOS NEED TO BE AT LEAST 3"X3". REVISE
 PHOTO THREE ON PAGE 6 OF 6.
  
 SEE ARCHITECT'S REVISION #8 ON PLANS AND REVISION
 #19110684 CITY RECORDS.
  
  
 3- FINAL SURVEY SUBMITTED:
 A) PROVIDE FINAL SURVEY SHOWING ALL THE ELEVATIONS
 REFERENCED IN THE ELEVATION CERTIFICATE. COORDINATE
 WITH ITEM #1.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 B) THE POOL SHOWS A TOP OF POOL FORM-BOARD ELEVATION OF
 14.49'. CLARIFY WHY IT IS A FORM-BOARD ELEVATION IF
 THIS IS A FINAL SURVEY.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]