Date |
Text |
2021-05-13 11:14:35 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. REVISION: 21041618 |
| W. P. B. PERMIT: 20071234 |
| ADD: 3950 GEORGIA AVE. |
| CONT: BUILTMORE CONTRACTING |
| TEL: 561-331-1476 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. MAY 13TH/ 2021 |
| ACTION: DENIED |
| |
| 1) THIS REVISION # 3 ON SHEET 1 OF 3 INDICATES THE |
| BUILDING CONSTRUCTION TYPE IS TYPE II CONSTRUCTION NO |
| WOOD FRAMING FOR THE BUILDING AND ROOF FRAMING MEMBERS. |
| THE REVISION INDICATES THE USE OF 2 X4 WOOD FRAMING |
| MEMBERS. PLEASE REVIEW IN THE 2017 FBC-B SECTION 603.1. |
| |
| 2A) THE LETTER INFORMS THE BUILDING DEPARTMENT THAT THE |
| EXISTING WINDOWS ARE NOT IMPACT RESISTANT TESTED AND |
| WILL APPLY AN APPROVED SHUTTER PANEL SYSTEM OVER THE |
| EXISTING WINDOWS. SUBMITTED IN THIS REVISION PACKAGE A |
| PRODUCT EVALUATION REPORT FOR 24 GAGE BERTH GALVANIZED |
| STEEL STORM SHUTTERS AND 10-PAGE TECHNICAL DRAWINGS BUT |
| NEITHER THE REPORT OR TECHNICAL DRAWINGS SHOW EITHER A |
| FLORIDA APPROVAL OR MIAMI-DADE NOA NUMBER. THIS REPORT |
| DOES NOT SHOW THEY HAVE A 3RD PARTY CERTIFICATION |
| PROGRAM. |
| COMPONENTS & CLADDING |
| 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| APPROVALS: |
| (31)( E ) STORM SHUTTERS |
| |
| 2B) STORM SHUTTERS. PROVIDE STORM PANEL INFORMATION |
| WITH INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| GLAZING. FBC 1609.1.2. |
| |
| FL BLD CODE 2010 SECTION 107.2.5., 1609.1.2, 1715.8 & |
| EXIST BUILD CODE 706.4 PROCEDURES: A COMPLETE |
| INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| WALL PRESSURE ZONES, SLAT TYPES, ETC. |
| |
| 2C) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP |
| DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD |
| PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC. |
| |
| 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 |
| IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/ |
| RETIRED. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |