2021-05-27 08:37:46 | 2ND REVIEW FBC-2020 PLUMBING |
| PERMIT-21041525 |
| 5/27/2021 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. COMMENTS 4, 5, 6, 8 |
| REMAINING FROM THE 1ST REVIEW ARE LISTED BELOW. IT |
| APPEARS THAT CORRECTED SHEET A2 WAS NOT UPLOADED. |
| |
| 4) FAILED. A1 & A2: SHOW THE 30X48 INCH CLEAR FLOOR |
| SPACE DIAGRAMS AND DIMENSIONS FOR THE NEW SINKS- |
| SECTIONS 606.2 & 305.1 FBC ACC. CLEAR FLOOR SPACE FOR |
| THE NURSES SINK NOT SHOWN. |
| |
| 5) FAILED. A2: PROVIDE ELEVATION DRAWINGS FOR THE NEW |
| SINKS THAT ARE COMPLIANT WITH FIGURE 306.3 FBC ACC. |
| CORRECTED SHEET A2 NOT UPLOADED FOR REVIEW. |
| |
| 6) FAILED. A2 DRINKING FOUNTAIN DETAIL: SHOW THE SPOUT |
| HEIGHT OF THE HI (STANDING PERSONS) DRINKING FOUNTAIN- |
| SECTION 602.7 FBC ACC. CORRECTED SHEET A2 NOT UPLOADED |
| FOR REVIEW. |
| |
| 8) FAILED. A1 & A2: INDICATE HOW THE WALLS SURROUNDING |
| THE MOP SINK WILL BE FINISHED IN COMPLIANCE WITH |
| SECTION 1210.2.2 FBC B. CORRECTED SHEET A2 NOT UPLOADED |
| FOR REVIEW. |
| |
| NEW COMMENT. |
| |
| 1) SHEET P1: IT APPEARS THAT THE BREAKROOM SINK IS NOT |
| SHOWN IN THE SANITARY RISER- SECTION 107.3.5.3.1 WPB. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |