Plan Review Notes For Permit 21041524 |
Permit Number |
21041524 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-05-11 12:44:41 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT-21041524 | | 5/11/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) P1: THE WATER HEATER COLD WATER INLET LINE REQUIRES | | A DEDICATED SHUT OFF VALVE THAT IS NOT SHOWN ON THE | | RISER- SECTION 503.1 FBC P. | | | | 2) D-1 & P1: SHOW AREA OF SLAB DEMOLITION AND PROVIDE A | | SLAB REPAIR DETAIL- SECTION 107.2.1 WPB. | | | | 3) A1 & A2: SHOW THE 30X48 INCH CLEAR FLOOR SPACE | | FORWARD APPROACH TO THE NEW SINK- SECTION 606.2 & | | FIGURE 305.5 FBC ACC. | | | | 4) A2: PROVIDE AN ELEVATION DRAWING FOR THE NEW SINK | | THAT IS COMPLIANT WITH FIGURE 306.3 FBC ACC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|