2021-06-17 12:59:25NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21041104
  
 1- FLOOR PLAN VIEW ON SHEET 1-3 SHOWS THE ENTRANCE OF
 THE BUILDING FACING SOUTH. SEE NORTH ARROW. TYPICALLY,
 THE ADDRESS OF THE BUILDING IS BASED ON THE ENTRANCE
 LOCATION. THE ADDRESS FOR THIS BUILDING IS ON CARVER
 AVE. BASED ON AN AERIAL VIEW CARVER AVE IS LOCATED ON
 THE WEST SIDE OF THIS LOT. THEREFORE, THE ORIENTATION
 OF THIS BUILDING AND THE EXTERIOR ELEVATIONS LABELING
 ON SHEET 1-3 NEEDS TO BE REVISED ACCORDINGLY. (NOTE:
 THIS IS AFFECTING THE ENERGY CALCULATIONS. THEY NEED TO
 BE REVISED ALSO. THIS IS WHY CORRECT ORIENTATION IS
 IMPORTANT).
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- ADDRESS AND PARCEL CONTROL NUMBER (PCN) SHOWN ON ALL
 PLANS SUBMITTED IS INCORRECT. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- PROVIDE SITE PLAN SHOWING THE PROPOSED BUILDING
 SETBACKS DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
 SEC. 107.2.5 CITY AMENDMENTS.
  
 4- SHEET 3-3:
 REVISE/CLARIFY THE ROOF SHEATHING NOTE NEXT TO THE ROOF
 PLAN UNDER THE COMPONENT AND CLADDING PRESSURE ZONES
 TABLE. THIS NOTE CONTRADICTS THE NAIL SPACING
 SPECIFICATIONS SHOWN ON THE COMPONENT AND CLADDING
 PRESSURE ZONES TABLE. REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 5-LOT DRAINAGE
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 6- REVISE ENERGY CALCULATIONS SUBMITTED:
 (NOTE: BUILDING ORIENTATION AFFECTS THE ENERGY
 CALCULATIONS. NEED TO COORDINATE WITH ITEM #1 ABOVE).
 A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PROVIDE CORRECT ADDRESS AND OWNER'S NAME, PROVIDE
 NAME OF BUILDER, PERMITTING OFFICE AND JURISDICTION
 NUMBER (THIS JURISDICTION IS 604700).
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)PROVIDE CORRECT INFORMATION FOR ITEM #2. THE QUESTION
 ON THIS ITEM IS SINGLE FAMILY OR MULTIPLE FAMILY?.
 "DETACHED" IS NOT THE ANSWER. REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 D) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT.
 (COORDINATE WITH ITEM #1 ABOVE).
 THIS BUILDING IS FACING CARVER AVE. THESE DOORS ARE
 LOCATED IN THE FRONT AND REAR OF BUILDING. SEE
 SURVEY/SITE PLAN AND FLOOR PLAN AND REVISE AS REQUIRED.
 . THEREFORE, THE CORRECT ORIENTATION IS WEST AND EAST.
 REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 E)WINDOWS INFORMATION ON PAGE 3 OF 4 IS INCORRECT.
 (COORDINATE WITH ITEM #1 ABOVE).
 THIS BUILDING IS FACING CARVER AVE. SEE SURVEY/SITE
 PLAN AND FLOOR PLAN AND REVISE AS REQUIRED. THERE ARE
 NO WINDOWS ON THE SOUTH SIDE.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  