Date |
Text |
2021-08-30 14:49:54 | REVISION |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| AMENDMENTS |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| 1) DRAWING (A2.0A), (A1.0 - 6A), (A1.0A), (A1.1) SHOW |
| THE DOORS NUMBER 1 AND 2 BLOCKING THE EXIT CORRIDOR - |
| PLEASE CORRECT FBC 1005.7.1DOORS. |
| DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED |
| WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY |
| POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE |
| THAN ONE-HALF. |
| 2) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR HEIGHT |
| FROM THE FINISHED FLOOR TO THE "REFLECTIVE SURFACE" PER |
| FBC 603.3MIRRORS. |
| MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND. |
| 3) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET REAR |
| GRAB BAR DIMENSIONS FROM THE CENTER OF THE TIOLET PER |
| FBC 604.5.2REAR WALL. |
| THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
| 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET SIDE |
| GRAB BAR LOCATION DIMENSIONS PER FBC 604.5.1SIDE WALL. |
| THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| FROM THE REAR WALL. |
| 5) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER |
| HOLDER LOCATION DIMENSIONS FROM THE FACE OF THE TOILET |
| PER FBC 604.7DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR |
| 6) PLEASE SHOW THE RESTROOM FLOOR AND BASE BOARD FINISH |
| PER FBC 1210.2.1 FLOORS AND WALL BASES. |
| IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND |
| SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH |
| FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, |
| NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE |
| WALLS NOT LESS THAN 4 INCHES (DRYWALL IS NOT CONSIDERED |
| A HARD SURFACE). |
| 7) PLEASE SHOW WALL AROUND THE MOP/SERVICE SINK PER FBC |
| 1210.2.2 WALLS AND PARTITIONS. |
| WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR |
| STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS |
| SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY |
| MOISTURE. (DRYWALL IS NOT CONSIDERED A HARD SURFACE) |
| |