2021-05-19 09:37:12WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21040866
 ADD: 3901 S. FLAGLER DR. # 804 BUILDING BUILT IN 1986
 CONT: COUNHAN CONSTRUCTION LLC
 TEL: 561-585-0084
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. MAY 19TH/ 2021
 ACTION: DENIED
  
 NOTICE ONLY!!!!!! 4X FEE / NOTICE!!!!! FLORIDA STATUTE
 553.80(2)(B) 66666WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT FINDS
 IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW.
  
  
  
 1A) 2ND REVIEW. PLEASE NOTE THE 8 PAGE SPEC SHEETS ARE
 NOT CONSIDERED PRODUCT TESTING. WHERE SUPER SAM 125 IS
 INVOLVED WHEN TESTED ON A 6 INCH CONCRETE SLAB AND A
 QUARRY TILE IS INVOLVED THE IIC RATING OF 49. THEY ALSO
 DID A ONE TIME USE FIELD TEST WHERE A RESULT OF 50 IIC
 WAS ACHIEVED. THE PROBLEM WITH THIS PRODUCT IS THE IIC
 RATING ON A 6 INCH SLAB. BUILDINGS THAT ARE DOCUMENTED
 THROUGH THE BUILDING DEPARTMENT THAT HAVE 8 INCH
 CONCRETE SLABS DO NOT HAVE A PROBLEM WITH THIS PRODUCT,
 ON A 8 INCH CONCRETE SLAB AND QUARRY TILE A RESULT OF
 51 IIC IS ACHIEVED. THE CITY IS IN RECEIPT OF TESTING
 REPORT FOR SUPER SAM 125 THE COMPONENTS OF THE ASSEMBLY
 ARE, 6 INCH CONCRETE SLAB FLOOR CEILING ASSEMBLY
 OVERLAID WITH QUARRY TILE ON NAC ? INCH MEDIUM- BED
 MORTAR AND SUPER SAM MEMBRANE ON HOMASOTE ? INCH
 COMFORTBASE TESTED TO ASTM E 492/ ASTM 989-89 AND
 ACHIEVED A IIC OF 52. OUT OF THE 11 TEST SUBMITTED FOR
 THIS PRODUCT THIS IS THE ONLY ONE THAT ACHIEVES A IIC
 RATING OF 50 OR MORE.
  
 PLEASE BE AWARE THAT BOTH TEST STRUCTURE BORNE SOUND
 AND AIR BORNE SOUND DEAL WITH THE FLOOR/ CEILING
 ASSEMBLY AS STATED IN THE FIRST REVIEW, COMMENTS 2A &
 2B.
  
 1ST ROUND OF COMMENTS. THE PROPOSED FLOOR PLAN, FLOOR
 PLAN KEY NOTES, NOTE # 3 INDICATES THE USE OF ? INCH
 SUPER SAM 90 & 125 UNDERLAYMENT WITH PORCELAIN TILE.
 THE CONTRACTOR UPLOADED A SALES BROCHURE FOR PROFLEX
 MSC, MEGA SOUND CONTROL MEMBRANE WITH A FLAME SPREAD
 REPORT. THE CITY HAS NOT RECEIVED ANY APPROVED TESTING
 REPORTS FOR THIS PRODUCT ON A 6-INCH SLAB. DISCREPANCY
 IN PRODUCTS. PLEASE NOTE THE CITY IS IN RECEIPT OF
 TESTING REPORTS FOR SUPER SAM-125 UNDERLAYMENTS ON A
 6-INCH CONCRETE SLAB THE FLOOR TOPPING BEING TRAVERTINE
 TILE, THE IIC OF 51 AND STC OF 54. AND FLAME SPREAD
 REPORT. NO REPORTS FOR SUPER SIM 90.
 1B) IF THE PRODUCT VARIES FROM WHAT THE DESIGNER OF
 RECORD REQUEST A SHOP DRAWING STAMP OF APPROVAL MUST
 ACCOMPANY THE FLOORING UNDERLAYMENT REPORTS. FL
 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
 2) FLOOR INSULATION (FBC-B 2020) FOR TILE, STONE,
 MARBLE, VINYL AND WOOD FLOORING ALL NEED TO HAVE HAD
 THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE
 FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED
 UNDER EACH OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR
 ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  