Plan Review Notes
Plan Review Notes For Permit 21031623
Permit Number 21031623
Review Stop NFIP
Sequence Number 3
Notes
Date Text
2021-10-16 10:41:52NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
 CITY ORDINANCE NO. 4658-16
  
 3RD REVIEW
  
 RE: CONSTRUCTION DRFAWING ELEVATION CERTIFICATE
  
 RESULTS: DENIED
  
 NOTICE:
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD
 ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS
 SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A
 SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758.
  
 2020 FBC EXISTING BUILDING
 1201.3FLOOD HAZARD AREAS.
 IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING
 REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF
 OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL
 IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH
 SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR
 SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL,
 AS APPLICABLE.
  
 CITY ORDINANCE NO. 4658-16
  
 CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16
 AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT
 AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE
 MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD
 HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM
 BEACH, FL.
  
 ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON
 NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM
 BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A
 TWO-FOOT FREEBOARD ABOVE THE (BFE).
 FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION
 PLAN AND/OR FLOOR PLAN.
  
 PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA
 (SFHA) WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' NAVD.
 DESIGN FLOOD ELEVATION (DFE) SHALL BE 8.0' NAVD OR
 HIGHER.
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT:
  
 1. LINE A7- BLDG. DIAGRAM NUMBER SHOULD BE 1B.
  
 2. LINE A8- THERE IS NO INDICATION ON THE PLANS
 SUBMITTED FOR REVIEW THAT THE BUILDING HAS A CRAWL
 SPACE.
  
 3. LINE C1- THIS IS THE CONSTRUCTION DRAWING ELEVATION
 CERTIFICATE, NOT THE FINISHED CONSTRUCTION EC.
  
 4. LINES C2 A THRU H)- ENTER DATA CONSISTANT WITH THE
 DFE OF 8.0' NAVD.
  
 5. SECTION D COMMENTS- COMMENTS SHALL BE CONSISTANT
 WITH THE DFE OF 8.0'NAVD.
  
 NOTICE: THIS PROPERTY IS LOCATED IN A HISTORIC
 DISTRICT. OWNERS HAVE SUBMITTED APPLICATION TO THE
 CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS (CBAA)
 FOR A FLOOD VARIANCE.
 NOH ON 10-21-2021.
  
  
  


Account Summary | Usage Policy | Privacy Policy