Date |
Text |
2021-10-16 10:41:52 | NFIP PLAN REVIEW |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER BUILDING - PX3169 |
| PLANS EXAMINER 1&2 FAMILY - SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| 2017 NEC |
| CITY ORDINANCE NO. 4658-16 |
| |
| 3RD REVIEW |
| |
| RE: CONSTRUCTION DRFAWING ELEVATION CERTIFICATE |
| |
| RESULTS: DENIED |
| |
| NOTICE: |
| |
| PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| (SFHA). IT IS LOCATED IN ZONE AE WITH A BASE FLOOD |
| ELEVATION OF 6.0 FEET NAVD. BASED ON THE VALUE OF THIS |
| SUBMITTAL, THE WORK ON THE PROPERTY IS CONSIDERED A |
| SUBSTANTIAL IMPROVEMENT (S/I) PER FEMA P-758. |
| |
| 2020 FBC EXISTING BUILDING |
| 1201.3FLOOD HAZARD AREAS. |
| IN FLOOD HAZARD AREAS, IF ALL PROPOSED WORK, INCLUDING |
| REPAIRS, WORK REQUIRED BECAUSE OF A CHANGE OF |
| OCCUPANCY, AND ALTERATIONS, CONSTITUTES SUBSTANTIAL |
| IMPROVEMENT, THEN THE BUILDING SHALL COMPLY WITH |
| SECTION 1612 OF THE FLORIDA BUILDING CODE, BUILDING, OR |
| SECTION R322 OF THE FLORIDA BUILDING CODE, RESIDENTIAL, |
| AS APPLICABLE. |
| |
| CITY ORDINANCE NO. 4658-16 |
| |
| CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 |
| AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT |
| AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE |
| MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD |
| HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM |
| BEACH, FL. |
| |
| ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED ON |
| NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST PALM |
| BEACH, BY ORDINANCE, NO. 4658-16, ESTABLISHED A |
| TWO-FOOT FREEBOARD ABOVE THE (BFE). |
| FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION |
| PLAN AND/OR FLOOR PLAN. |
| |
| PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| (SFHA) WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' NAVD. |
| DESIGN FLOOD ELEVATION (DFE) SHALL BE 8.0' NAVD OR |
| HIGHER. |
| |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT: |
| |
| 1. LINE A7- BLDG. DIAGRAM NUMBER SHOULD BE 1B. |
| |
| 2. LINE A8- THERE IS NO INDICATION ON THE PLANS |
| SUBMITTED FOR REVIEW THAT THE BUILDING HAS A CRAWL |
| SPACE. |
| |
| 3. LINE C1- THIS IS THE CONSTRUCTION DRAWING ELEVATION |
| CERTIFICATE, NOT THE FINISHED CONSTRUCTION EC. |
| |
| 4. LINES C2 A THRU H)- ENTER DATA CONSISTANT WITH THE |
| DFE OF 8.0' NAVD. |
| |
| 5. SECTION D COMMENTS- COMMENTS SHALL BE CONSISTANT |
| WITH THE DFE OF 8.0'NAVD. |
| |
| NOTICE: THIS PROPERTY IS LOCATED IN A HISTORIC |
| DISTRICT. OWNERS HAVE SUBMITTED APPLICATION TO THE |
| CONSTRUCTION BOARD OF ADJUSTMENTS AND APPEALS (CBAA) |
| FOR A FLOOD VARIANCE. |
| NOH ON 10-21-2021. |
| |
| |
| |