Plan Review Notes For Permit 21031564 |
Permit Number |
21031564 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-04-21 15:51:50 | STAIR SHOP DRAWINGS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW WALL FRAMING DETAILS. | | 2) PLEASE SHOW RESTROOMS TO COMPLY WITH FBC | | ACCESSIBILITY PER CHAPTER 6 - USE DIMENSIONS TO SHOW | | (GRAB BAR HEIGHTS, LOCATIONS AND LENGHTS FOR WATER | | CLOSET AND SHOWER) - (DOOR WIDTHS) - (PAPER DISPENSER | | LOCATION AND DISTANCE FROM WATER CLOSET, HEIGHT FROM | | FLOOR) - ( FIXTURE CLEAR FLOOR SPACE) (ETC..) | | 3) RESTROOM DOOR NEEDS A CLEAR OPENING BETWEEN ANY TRIM | | OR STOPS OF 32" FBC 404.2.3 CLEAR WIDTH. | | DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES | | (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | 4) PLEASE SHOW THE OCCUPANCY CLASSIFICATION PER FBC | | CHAPTER 3 |
|