Plan Review Notes For Permit 21031501 |
Permit Number |
21031501 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-04-09 15:29:43 | COMMERCIAL ALTERATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE DOOR SWING ENCROACHMENT INTO THE | | EGRESS CORRIDOR TO COMPLY WITH FBC 1005.7 ENCROACHMENT. | | ENCROACHMENTS INTO THE REQUIRED MEANS OF EGRESS WIDTH | | SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THIS | | SECTION. FBC 1005.7.1 DOORS. | | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED | | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY | | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE | | THAN ONE-HALF. | | 2) A NEW OPENING IS BEING ADDED TO THE ELEVATOR LOBBY - | | PLEASE SHOW THE ELEVATOR HOISTWAY PROTECTION PER FBC | | 3006.3 | | 3) PLEASE SHOW EXIT SIGNS WHERE REQUIRED PER FBC 1013.1 | | |
|