2021-08-17 10:53:23 | 1ST REVIEW FBC-2020 PLUMBING |
| PERMIT- 21031268 |
| 8/17/2021 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) PROVIDE A PLUMBING PLAN SHOWING THE SCOPE OF WORK |
| FOR DEMOLITION AND ALTERATIONS. SHEET 2.0 APPEARS TO |
| SHOW A SINK IS BEING REMOVED AND A WATER COOLER IS |
| BEING INSTALLED. PLEASE REFER TO SECTIONS 211.1 & 211.2 |
| FBC ACC- WHERE DRINKING FOUNTAINS ARE PROVIDED NO FEWER |
| THAN TWO SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL |
| BE A LO AND THE OTHER A HI. PLEASE SEE SECTIONS 602.1- |
| 602.6, 602.7, 306 & 307 AND PROVIDE INSTALLATION |
| DETAILS INCLUDING ELEVATION VIEWS SHOWING KNEE AND TOE |
| CLEARANCES, SPOUT HEIGHTS, AND SPOUT LOCATIONS. SHOW |
| THE REQUIRED 30 X 48 IN. CLEAR FLOOR SPACE FOR A |
| FORWARD WHEELCHAIR APPROACH TO THE FOUNTAIN- SECTION |
| 602.2 FBC ACC, AND SHOW HOW THE LOCATIONS OF THE |
| FOUNTAINS WILL BE IN COMPLIANCE WITH SECTION 307.2 |
| PROTRUSION LIMITS. |
| |
| 2) PROVIDE SANITARY DRAINAGE AND WATER RISER DRAWINGS |
| FOR REQUIRED DRINKING FOUNTAIN PLUMBING PIPING |
| INSTALLATIONS- SECTION 107.3.5.1.3 WPB. |
| |
| 3) PROVIDE A SLAB REPAIR DETAIL FOR INSTALLATION OF |
| UNDERSLAB DRAIN PIPING- SECTION 107.2.1 WPB. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |