2021-04-22 16:04:50 | 1ST REVIEW FBC-2020 RES. |
| PERMIT- 21031243 |
| 4/22/2021 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| 2020 |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEETS A100, A101, & A400: THE SANITARY RISER |
| DRAWING DOES NOT INCLUDE THE ALTERED SANITARY PIPING IN |
| THE KITCHEN, MASTER BATH, AND THE 2ND FLOOR BATH- |
| SECTION 107.3.5.3 WPB. |
| |
| 2) A400: CORRECT THE RISER TO SHOW A 2 IN. STANDPIPE |
| FOR THE WASHING MACHINE CONNECTING TO A 3 IN. STACK- |
| SECTION 406.2 FBC P. |
| |
| 3) A101: PROVIDE THE DIMENSIONS OF THE SHOWERS IN THE |
| GUEST BATH AND 2ND FLOOR BATH- SECTION P2708.1 FBC RES. |
| |
| 4) PROVIDE SHOWER PAN DETAILS FOR THE MASTER BATH, |
| GUEST BATH, AND 2ND FLOOR BATH- SECTION P2709.1 & |
| P2709.2 FBC RES. |
| |
| 5) PROVIDE SHOWER AND BATHTUB VALVE COMPLIANCE |
| INFORMATION ON THE PLAN- SECTIONS P2708.4 & P2713.3 FBC |
| RES. |
| |
| 6) PROVIDE IRRIGATION PLANS OR INDICATE THE PLANS WILL |
| BE SUBMITTED UNDER SEPARATE PERMIT- SECTION 105.1 & |
| 107.2.1 WPB. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |
| |