2021-03-26 16:49:13 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): |
| 1. PROVIDE A GRAPHIC OF THE EXISTING DOOR AND PROPOSED |
| DOOR. |
| 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE |
| WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF |
| AT [email protected] TO REQUEST THE EXAMPLE. AT |
| MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOW |
| MATERIAL AND THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, |
| GLASS GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION |
| WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW |
| MARKED. |
| 3. INCLUDE THE ORDER QUOTE DETAIL. |
| 4. REVISE TO CLEAR OR CLEAR GLASS WITH LOW-E DEPENDING |
| ON ELEVATION. SEE CONDITION #3 |
| 5. REVISE LITE PATTERN TO MATCH EXISTING. |
| 6. CLARIFY PRODUCT TO BE USED. CGI AND PGT HAVE VERY |
| DIFFERENT MUNTIN PROFILES AVAILABLE. |
| 7. THE FRONT STREET FACING PAIRED CASEMENT APPEARS TO |
| BE WOOD. THESE WINDOWS WILL NEED TO BE RETAINED AND |
| SHOULD BE RESTORED. |
| 8. CLARIFY/ENSURE THAT THE WINDOW IS ONE WINDOW IF |
| USING A HOPPER/AWNING. AWNING WINDOWS TRADITIONALLY ARE |
| MADE OF MULTIPLE PANELS AND ARE MID-CENTURY ELEMENT NOT |
| APPROPRIATE FOR A 1920S HOUSE. |
| |
| PROPOSED CONDITIONS, SUBJECT TO CHANGE: |
| 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE |
| ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND |
| MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL |
| WINDOWS. |
| 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED |
| WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. |
| 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. |
| ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR |
| WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS |
| MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. |
| |