Date |
Text |
2021-03-31 08:22:00 | BUILD OUT |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected]. |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENTS |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| |
| 1) RESTROOM MIRROR HEIGHT NEEDS TO BE SHOWN TO COMPLY |
| WITH FBC A603.3 MIRRORS. |
| MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| BE INSTALLED WITH THE *** BOTTOM EDGE OF THE REFLECTING |
| SURFACE *** 40 INCHES (1015 MM) MAXIMUM ABOVE THE |
| FINISH FLOOR OR GROUND. |
| |
| 2) HAND TOWEL DISPENSER - THE HEIGHT OF THE TOWEL |
| OUTLET NEEDS TO BE SHOWN TO COMPLY WITH FBC A308.1 |
| GENERAL. |
| REACH RANGES SHALL COMPLY WITH FBC ACCESSIBILITY 308. |
| |
| 3) RESTROOM BASE BOARD SHOULD NOT BE WOOD - PLEASE |
| COMPLY WITH FBC 1210.2.1 FLOORS AND WALL BASES. |
| IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND |
| SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH |
| FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, |
| NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE |
| WALLS NOT LESS THAN 4 INCHES (102 MM). |
| |
| 4) DRAWING A1.1.1 RESTROOM SHOWS ONLY 1 WALL OF TILE - |
| ALL WALLS NEXT TO THE TOILET NEED TO COMPLY WITH FBC |
| 1210.2.2 WALLS AND PARTITIONS. |
| WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| THAN 4 FEET (1219 MM) ABOVE THE FLOOR |