Plan Review Notes
Plan Review Notes For Permit 21030654
Permit Number 21030654
Review Stop B
Sequence Number 1
Notes
Date Text
2021-04-07 07:47:22PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SPACING OF THE VERTICAL MEMBERS OF THE SHADOW
 BOX FENCE IS SPECIFIED AS 2 INCHES. THE SPACING OF
 VERTICAL MEMBERS CAN NOT EXCEED 1-3/4 INCHES.
 FBC-R4501.17.1.4 WHERE THE BARRIER IS COMPOSED OF
 HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE
 BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN
 45 INCHES (1143 MM), THE HORIZONTAL MEMBERS SHALL BE
 LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING
 BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4 INCHES
 (44 MM) IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS
 WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS
 SHALL NOT EXCEED 1-3/4 INCHES (44 MM) IN WIDTH.