Plan Review Notes For Permit 21030131 |
Permit Number |
21030131 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2021-03-31 14:55:10 | WINDOWS AND DOORS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) FLOOR PLAN SHOWS BEDROOM WINDOWS 12,13,14, AND 15 AS | | FIXED GLASS WINDOWS - BEDROOMS NEED TO COMPLY WITH FBC | | R310.2.5 | | 2) A SINGLE HUNG WINDOW PRODUCT APPROVAL IS PROVIDED - | | THE FLOOR PLAN DRAWINGS DO NOT SHOW A SINGLE HUNG | | WINDOW - PLEASE CLARIFY. | | |
|