Plan Review Notes
Plan Review Notes For Permit 21030009
Permit Number 21030009
Review Stop B
Sequence Number 3
Notes
Date Text
2021-06-25 14:00:3906/25/21 RESPONSE TO REAGAN BRENNER:
  
 GOOD MORNING TO ALL. MR. GOMEZ, I AM WORKING ON THE
 REVISION OF THE GARAGE ELEVATION CERTIFICATE FOR MR.
 AND MRS. FARINO THIS MORNING. I WOULD LIKE TO ASK FOR A
 HELP WHILE THE NEW PHOTO IS PENDING.
 I HAVE REVISED THE VENTING INFORMATION IN SECTION A8 A
 & C. AS THIS IS NOT FINALIZED, MAY I ASK FOR YOUR
 REVIEW TO ENSURE WE ARE ON FIRM GROUND TO MOVE FORWARD?
 IF SO, WE WILL ADD THE UPDATED PHOTOGRAPH PROVIDED BY
 MR. AND MRS. FARINO SHOWING THE 6TH VENT ADDED. WILL
 THIS BE SUFFICIENT FOR THEIR SUBMITTAL? WE REALLY WANT
 TO HELP GET THEIR PROJECT COMPLETED FOR THEM. THANK YOU
 SO MUCH FOR YOUR GUIDANCE.
 THANK YOU,
 REAGAN BRENNER
 COMPASS SURVEYING
 6250 NORTH MILITARY TRAIL, SUITE 102
 WEST PALM BEACH, FL 33407
 1-800-226-4807
  
  
  
 GOOD AFTERNOON MR. BRENNER,
 THE ELEVATION CERTIFICATE YOU SENT ME DOESN'T PROVIDE
 ANY INFORMATION IN SECTION A8.
 RIGHT NOW, WE NEED TO WAIT UNTIL THE NEW FLOOD VENT IS
 INSTALLED. COORDINATED WITH MRS. FARINO. SHE ALSO HAS A
 COPY OF THE REVISED GARAGE SHOWING THE CORRECT GARAGE
 SQUARE FOOTAGE AND NUMBER OF REQUIRED FLOOD VENTS.
 ATTACHED PLEASE FIND A COPY OF THE FLOOD VENT PRODUCT
 APPROVAL SO YOU CAN FIND THE NET AREA OF EACH VENT.
 ALSO, I HAVE ATTACHED AC COPY OF THE FEMA ELEVATION
 CERTIFICATE INSTRUCTIONS. THE INSTRUCTIONS WILL HELP
 YOU TO SEE WHAT INFORMATION NEEDS TO BE COMPLETED AND
 HOW. THIS IS MY PERSONAL HIGHLIGHTED COPY (DISREGARD MY
 HIGHLIGHTING AND NOTES).
  
 IN ADDITION, I WANT TO EMPHASIZE THAT WE NEED AN
 ELEVATION CERTIFICATE FOR THE MAIN HOUSE AND ANOTHER
 ONE FOR THE GARAGE.
 PLEASE SEE COMMENTS BELOW FROM MY LAST REVIEW. CHECK
 THAT ALL INFORMATION IS COORDINATED WHEN YOU ARE READY
 TO PREPARE THE FINAL SURVEY AND FINAL ELEVATIONS
 CERTIFICATES.
 YOU CAN CONTACT ME IF YOU HAVE A SPECIFIC QUESTION.
 THANK YOU
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
 RESIDENTIAL(R3) ELEVATION CERTIFICATE. SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 5TH EDITION (2014) AND CITY AMENDMENTS.
 SUBMITTAL #21030009 (MASTER 16061174).
  
 COMMENTS FOR REVISED ELEVATION CERTIFICATE CERTIFIED ON
 05/06/2021 FOR MAIN HOUSE:
  
 1- ITEM A3 ON PAGE 1 OF 6 IS INCORRECT. THIS ITEM IS
 ASKING FOR THE PROPERTY DESCRIPTION. FORM SUBMITTED
 SAYS 1B. WHAT IS 1B? REVISE AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- ITEM C2(A) SHOWN ON PAGE 2 OF 6 DOESN'T MATCH FINISH
 FLOOR ELEVATION SHOWN ON SURVEY SUBMITTED. REVISE AS
 REQUIRED TO MATCH.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- ELEVATION OF LOWEST MACHINERY OR EQUIPMENT SHOWN ON
 ITEM C2(E) DOESN'T MATCH ELEVATION SHOWN ON SURVEY
 SUBMITTED. REVISE AS REQUIRED.
 NOTE: CLARIFY WHAT ARE THE ELEVATIONS 7.40', 7.45' AND
 7.44' SHOWN ON THE SURVEY NEXT TO THE A/C PADS?.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 4- ELEVATION OF LOWEST MACHINERY OR EQUIPMENT DOESN'T
 MEET THE CITY FREEBOARD REQUIREMENT OF 1 FOOT ABOVE THE
 BASE FLOOD ELEVATION AS REQUIRED BY CITY ORDINANCE
 4658-16.
 EQUIPMENT NEEDS TO BE RAISED AND ELEVATION CERTIFICATE
 NEEDS TO BE REVISED ACCORDINGLY.
 NOTE: ORIGINAL PLANS WERE APPROVED BEFORE THE NEW FLOOD
 MAPS TOOK EFFECT. PREVIOUS MAPS WERE BASED ON NGVD 1929
 ELEVATION DATUM. BASED ON NGVD, THE BASE FLOOD
 ELEVATION WAS 7 FEET AND THE REQUIRED FINISHED FLOOR
 ELEVATION WAS 8 FEET NGVD.
  
 5- COMMENTS ON SECTION D ON PAGE 2 OF 6 SPECIFIES A/C
 EQUIPMENT PAD LOCATED EASTERLY SIDE OF HOUSE. BASED ON
 SURVEY SUBMITTED, THIS IS INCORRECT. REVISE AS
 REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 6- ITEM C2(F) LOWEST ADJACENT GRADE AND ITEM
 C2(G)HIGHEST ADJACENT GRADE SHOWN CAN NOT BE VERIFIED
 BECAUSE SURVEY SUBMITTED DOESN'T SHOW THIS ELEVATIONS.
 PROVIDE SURVEY SHOWING THOSE ELEVATIONS.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 7- PHOTOS SHOWN ON PAGES 5 OF 6 AND PAGE 6 OF 6 NEED TO
 BE TAKEN WITHIN 90 DAYS FROM THE DATE OF CERTIFICATION.
 SEE FEMA ELEVATION CERTIFICATE INSTRUCTIONS (2019
 EDITION). THIS ELEVATION CERTIFICATE WAS CERTIFIED BY
 THE SURVEYOR ON 05/06/2021 WHEN THE EMBOSSED SEAL AND
 SIGNATURE WAS APPLIED. THE PHOTOS PROVIDED ARE DATED
 04/03/2020 AND IT LOOKS LIKE THEY WERE TAKEN WHEN THE
 BUILDING WAS UNDER CONSTRUCTION. PROVIDE CURRENT
 PHOTOS.
 NOTE: ALSO, REVISE THE DATE SHOWN BY THE BOTTOM MIDDLE
 AREA OF SECTION D. IT SAYS 4/3/2020. THIS DATE IS ONE
 YEAR OLD. IT SHOULD BE THE SAME DATE AS DATE OF
 CERTIFICATION.
  
  
 COMMENTS FOR ELEVATION CERTIFICATE CERTIFIED ON
 05/06/2021 FOR GARAGE:
  
 1- REVISE/CLARIFY DESCRIPTION ON ITEM A4 ON PAGE 1 OF
 6. WHAT IS A "DEATTACHED GARAGE"?. REVISE/CLARIFY AS
 REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- ITEM A7 ON PAGE 1 OF 6 IS INCORRECT. THERE IS NOT
 CRAWLSPACE IN THE GARAGE. REVISE AS REQUIRED.
 SEC. 107..2.1 CITY AMENDMENTS.
  
 3- SQUARE FOOTAGE SPECIFIED ON ITEM A8(A) ON PAGE 1 OF
 6 IS INCORRECT. ACCORDING TO SURVEY SUBMITTED THE
 GARAGE SQUARE FOOTAGE IS 733 S.F. NOT 586 S.F. REVISE
 AS REQUIRED. NOTE: SQUARE FOOTAGE IS TAKEN FROM
 EXTERIOR WALLS.
 SEC. 107..2.1 CITY AMENDMENTS.
  
 4- TOTAL NET AREA OF FLOOD OPENINGS SPECIFIED ON ITEM
 A8(C) ON PAGE 1 OF 6 IS INCORRECT. SURVEYOR PROVIDED
 COMMENT AT BOTTOM OF SECTION D STATING "VENTING BASED
 ON FLOOD SOLUTIONS VENTS FS 1412 PER CLIENTS".
 ACCORDING TO ENGINEERED VENT PRODUCT APPROVAL FL17588
 SUBMITTED WITH PERMIT APPLICATION #16061174 THE
 SELECTED VENT FS-1412 HAS A NET FREE AREA OF 106.7 SQ.
 IN. PER VENT. IF THERE ARE 5 VENTS, THEN THE TOTAL NET
 AREA IS 533.5 SQ. IN. NOT 1000 SQ. IN. REVISE AS
 REQUIRED. NOTE: COORDINATE WITH ITEM #5 BELOW.
 SEC. 107..2.1 CITY AMENDMENTS.
  
 5- BASED ON ITEMS #3 AND #4 ABOVE IT LOOKS LIKE THE
 ENGINEER OF RECORD FOR PERMIT #16061174 NEEDS TO REVISE
 THE PLANS AND NUMBER OF REQUIRED FLOOD VENTS. SHEET A-2
 SPECIFIES A GARAGE AREA OF 586 S.F. ALSO, ENGINEER
 SHOWS 5 FLOOD VENTS (MODEL FS-1412 PRODUCT APPROVAL
 FL17588) ON WEST AND EAST WALLS.
 ENGINEER OF RECORD NEEDS TO PROVIDE CORRECT GARAGE
 SQUARE FOOTAGE AND REVISE THE NUMBER OF REQUIRED VENTS.
 SUBMIT REVISE PLANS FOR REVIEW. REVISION FEES APPLY.
 SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: SQUARE FOOTAGE IS TAKEN FROM EXTERIOR WALLS.
  
 6- ITEM C2(A) SHOWN ON PAGE 2 OF 6 DOESN'T MATCH FINISH
 FLOOR ELEVATION SHOWN ON SURVEY SUBMITTED. REVISE AS
 REQUIRED TO MATCH.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 7- ITEM C2(B) SHOWN ON PAGE 2 OF 6 IS INCORRECT. THERE
 IS NOT NEXT HIGHER FLOOR IN THE GARAGE. REVISE AS
 REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 8- ITEM C2(F) LOWEST ADJACENT GRADE AND ITEM
 C2(G)HIGHEST ADJACENT GRADE SHOWN CAN NOT BE VERIFIED
 BECAUSE SURVEY SUBMITTED DOESN'T SHOW THIS ELEVATIONS.
 PROVIDE SURVEY SHOWING THOSE ELEVATIONS.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 9- PHOTOS SHOWN ON PAGES 5 OF 6 AND PAGE 6 OF 6 NEED TO
 BE TAKEN WITHIN 90 DAYS FROM THE DATE OF CERTIFICATION.
 SEE FEMA ELEVATION CERTIFICATE INSTRUCTIONS (2019
 EDITION). THIS ELEVATION CERTIFICATE WAS CERTIFIED BY
 THE SURVEYOR ON 05/06/2021 WHEN THE EMBOSSED SEAL AND
 SIGNATURE WAS APPLIED. THE PHOTOS PROVIDED ARE DATED
 04/03/2020 AND IT LOOKS LIKE THEY WERE TAKEN WHEN THE
 BUILDING WAS UNDER CONSTRUCTION. PROVIDE CURRENT
 PHOTOS.
 NOTE: ALSO, REVISE THE DATE SHOWN BY THE BOTTOM MIDDLE
 AREA OF SECTION D. IT SAYS 4/3/2020. THIS DATE IS ONE
 YEAR OLD. IT SHOULD BE THE SAME DATE AS DATE OF
 CERTIFICATION.
  
  
 REVISE SURVEY SUBMITTED:
  
 1- SURVEY SUBMITTED IS AN SPECIFIC PURPOSE
 SURVEY-"NORTHERLY FORMBOARDTIE IN". SEE TOP OF SURVEY.
 IF THIS SURVEY IS FOR ELEVATION CERTIFICATE FINISHED
 CONSTRUCTION, THEN THE SURVEY SHOULD BE A FINAL SURVEY
 AS WELL NOT A FORMBOARD SURVEY. PROVIDE FINAL SURVEY.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 2- FLOOD ZONE INFORMATION SPECIFIED AT THE BOTTOM
 MIDDLE OF SHEET IS OLD. THE CURRENT FLOOD MAP WENT INTO
 EFFECT ON 10/05/2017. REVISE ALL FLOOD INFORMATION AS
 REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 3- SURVEY DOESN'T MATCH APPROVED PLANS AND PHOTOS SHOWN
 ON THE ELEVATION CERTIFICATES. THERE IS A BREEZEWAY
 CONNECTING THE GARAGE TO THE MAIN HOUSE. REVISE AS
 REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 4- PROVIDE REVISED SURVEY WITH SURVEYORS ORIGINAL
 SEAL/SIGNATURE AS REQUIRED BY CHAPTER 472 F.S. WHEN
 SUBMITTING DOCUMENTS FOR PUBLIC RECORDS.
 NOTE: THIS CAN BE ACHIEVED BY UPLOADING DOCUMENTS WITH
 SURVEYOR'S DIGITAL SIGNATURE OR BY PROVIDING HARD COPY
 PLANS/DOCUMENTS WITH SURVEYOR'S ORIGINAL
 SEAL/SIGNATURE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  