Plan Review Notes For Permit 21020808 |
Permit Number |
21020808 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-03-03 15:32:59 | SHUTTERS | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE CHECK YOUR ATTACHMENTS SHOWN ON THE | | ATTACHMENT FORM - USING A TAPPER IN CONCRETE ON | | CONNECTION "A" WITH AN EDGE DISTANCE OF 2.5 YOU WOULD | | NEED TO MULTIPLY THE REQUIRED SPACING SHOWN ON THE | | CHART BY (.67) - SEE ATTACHMENT SCHEDULE ON PG 13 OF 20 | | - PLEASE CHECK ALL ATTACHMENT SPACINGS. |
|