Plan Review Notes
Plan Review Notes For Permit 21020630
Permit Number 21020630
Review Stop B
Sequence Number 2
Notes
Date Text
2021-03-19 15:34:40PLAN REVIEW / ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS
  
  
 NOTICE: SITE SPECIFIC DESIGN WIND LOADS PER FBC R301
 TABLE R301.2(2) (-89.4PSF) AND TABLE R301.2(3)
 (ADJUSTMENT COEFFICIENT OF 1.21 ARE -108.17PSF
 PRODUCT APPROVAL FL16717-R10 PROVIDES A MDP OF -60.0PSF
 (SYSTEM W-124 SELECTED)
  
 1. PROVIDE ENHANCED FASTENER CALCULATIONS FOR ZONES 2
 AND 3 PREPARED BY A DESIGN PROFESSIONAL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 NEW COMMENTS:
  
 1. SYSTEMS W-122, W-126 AND W-129 WOULD GIVE YOU A
 DESIGN PRESSURE OF -112.5 AND WOULD BE APPROVED FOR
 INSTALLATION.
  
 2. PRODUCT APPROVAL 17442-R5 (LIQUID APPLIED ROOF
 SYSTEMS), WAS SUBMITTED FOR REVIEW. SYSTEM C-17 IS
 SELECTED TO BE INSTALLED. THIS SYSTEM IS FOR CONCRETE
 DECKS.
 ARE YOU PROPOSING A CHANGE IN THE SCOPE OF WORK? IF SO,
 PROVIDE A CHANGE ORDER, SIGNED BY OWNER.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PROVIDE CLARIFICATION.