2021-01-07 08:36:03 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) SUBMIT REQUIRED COMPONENT AND CLADDING DESIGN |
| PRESSURES FOR THE OPENINGS THAT HAVE BEEN PREPARED BY A |
| FLORIDA LICENSED ENGINEER. THE DOCUMENTS ARE REQUIRED |
| TO BE DIGITALLY SIGNED BY THE ENGINEER IF SUBMITTED |
| ELECTRONICALLY AND THE ENGINEER'S ORIGINAL HANDWRITTEN |
| SIGNATURE IF PAPER DOCUMENTS ARE SUBMITTED. FS 471 & |
| FAC 61G15 |
| |
| 2) ELEVATIONS OF THE BUILDING SHOWING THE WALL ZONES |
| AND REQUIRED PRESSURES, A WINDOW AND DOOR SCHEDULE WITH |
| THE OPENING SIZES, REQUIRED PRESSURES, PRODUCT APPROVAL |
| NUMBER AND DESIGN PRESSURE FROM THE PRODUCT APPROVAL IS |
| REQUIRED. FBC 107.2.1.2 |
| |
| 3) HI-LIGHT OR CIRCLE THE SPECIFIC DETAILS AND DESIGN |
| PRESSURES THAT APPLY TO THIS PROJECT IN THE WINDOW AND |
| DOOR PRODUCT APPROVALS. FBC 107.2.1 |
| |
| 4) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED |
| AND APPROVED BY THE DESIGNER OF RECORD FOR THE PROJECT. |
| FBC 107.3.4 |
| |
| 5) PURSUANT TO FBC 107.1, AND FS 481.229 (1) (C), AS |
| THIS THIS DESIGN EXCEEDS $25,000.00 IN VALUE, THE |
| DESIGN MUST BE PREPARED BY A PROFESSIONAL LICENSED |
| PURSUANT TO FS 481. SEE BELOW: |
| FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF |
| CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL |
| INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL |
| BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT |
| APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE |
| PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE |
| REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15 |
| FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA |
| STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE. WHERE |
| SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL IS |
| AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS |
| TO BE PREPARED BY A |
| REGISTERED DESIGN PROFESSIONAL. ELECTRONIC MEDIA |
| DOCUMENTS SHALL BE SUBMITTED WHEN REQUIRED BY THE |
| BUILDING OFFICIAL, AND MAY REQUIRE ONLY ONE SET OF |
| SUBMITTALS. |
| |
| 6) THE REPAIR DRAWINGS AND DETAILS ARE REQUIRED TO BE |
| SIGNED AND SEALED BY THE DESIGNER OF RECORD AND HAVE A |
| TITLE BLOCK. |
| 61G15-23.001 SIGNATURE, DATE AND SEAL SHALL BE AFFIXED. |
| (1) A PROFESSIONAL ENGINEER SHALL SIGN, DATE AND SEAL: |
| (A) ALL FINAL PLANS, PRINTS, SPECIFICATIONS, REPORTS, |
| OR OTHER DOCUMENTS PREPARED OR ISSUED BY THE LICENSEE |
| AND BEING FILED FOR PUBLIC RECORD; |
| (B) ALL FINAL DOCUMENTS PROVIDED TO THE OWNER OR THE |
| OWNER'S REPRESENTATIVE. |
| (2) ADDITIONAL FINAL AND NON-FINAL DOCUMENTS. |
| (A) A PROFESSIONAL ENGINEER MAY SIGN, DATE AND SEAL |
| DOCUMENTS REQUIRED BY ANY PUBLIC ENTITY OR ANY |
| PROVISION OF CONTRACT WHICH REQUIRES THE SIGNING, |
| DATING AND SEALING OF ADDITIONAL ORIGINAL DOCUMENTS. |
| (B) A PROFESSIONAL ENGINEER SHALL NOT SIGN, DATE AND |
| SEAL ANY DOCUMENTS WHICH ARE NOT FINAL DOCUMENTS UNLESS |
| THE PROFESSIONAL ENGINEER STATES ANY LIMITATIONS ON THE |
| USE OF THOSE DOCUMENTS ON THE FACE OF THOSE DOCUMENTS |
| BY USING TERMS SUCH AS ?PRELIMINARY,? ?FOR REVIEW |
| ONLY,? ?NOT FOR CONSTRUCTION,? OR ANY OTHER SUITABLE |
| STATEMENT WHICH DENOTES THAT THE DOCUMENTS ARE FOR |
| LIMITED USE, ARE NOT FINAL AND ARE NOT INTENDED FOR |
| PERMIT, CONSTRUCTION, OR BIDDING PURPOSES. |
| (3) A PROFESSIONAL ENGINEER MAY ONLY SIGN, DATE AND |
| SEAL ENGINEERING PLANS, PRINTS, SPECIFICATIONS, REPORTS |
| OR OTHER DOCUMENTS IF THAT PROFESSIONAL ENGINEER WAS IN |
| RESPONSIBLE CHARGE, AS THAT TERM IS DEFINED IN |
| SUBSECTION 61G15-18.011(1), F.A.C., OF THE PREPARATION |
| AND PRODUCTION OF THE ENGINEERING DOCUMENT AND THE |
| PROFESSIONAL ENGINEER HAS THE EXPERTISE IN THE |
| ENGINEERING DISCIPLINE USED IN PRODUCING THE |
| ENGINEERING DOCUMENT(S) IN QUESTION. PROFESSIONAL |
| ENGINEERS WORKING FOR LOCAL, STATE OR FEDERAL |
| GOVERNMENT AGENCIES SHALL LEGIBLY INDICATE THEIR NAME |
| AND LICENSE NUMBER AND SHALL INDICATE THE NAME AND |
| ADDRESS OF THE AGENCY ON ALL DOCUMENTS THAT ARE |
| REQUIRED TO BE SIGNED, DATED AND SEALED. |
| (4) ADDITIONAL REQUIREMENTS FOR PLANS OR PRINTS, |
| ENGINEERING SPECIFICATIONS AND CALCULATIONS, AND |
| ENGINEERING REPORTS OR OTHER DOCUMENTS. WHEN AN |
| ENGINEER SIGNS, DATES AND SEALS ANY OF THE FOLLOWING |
| TYPES OF DOCUMENTS PLANS OR PRINTS UNDER THE PROVISIONS |
| OF SECTION 471.025, F.S., AND SUBSECTION (1) OF THIS |
| RULE, THE FOLLOWING ADDITIONAL INFORMATION MUST BE |
| INCLUDED: |
| (A) PLANS AND PRINTS. EVERY SHEET WITHIN THE PLANS AND |
| PRINTS MUST BE SIGNED, DATED AND SEALED BY THE |
| PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. |
| 1. A TITLE BLOCK SHALL BE USED ON EACH SHEET OF PLANS |
| OR PRINTS AND SHALL CONTAIN THE PRINTED NAME, ADDRESS, |
| AND LICENSE NUMBER OF THE ENGINEER WHO HAS SIGNED, |
| DATED AND SEALED THE PLANS OR PRINTS. |
| 2. IF THE ENGINEER SIGNING, DATING AND SEALING |
| ENGINEERING PLANS OR PRINTS IS PRACTICING THROUGH A |
| DULY AUTHORIZED QUALIFIED ENGINEERING BUSINESS |
| ORGANIZATION; THE TITLE BLOCK SHALL CONTAIN THE PRINTED |
| NAME AND ADDRESS OF THE QUALIFIED ENGINEERING BUSINESS |
| ORGANIZATION. |
| (B) ENGINEERING SPECIFICATIONS AND CALCULATIONS. AN |
| INDEX SHEET SHALL BE USED AND SHALL BE SIGNED, DATED |
| AND SEALED BY EACH PROFESSIONAL ENGINEER WHO IS IN |
| RESPONSIBLE CHARGE OF ANY PORTION OF THE ENGINEERING |
| SPECIFICATIONS OR CALCULATIONS. |
| 1. THE INDEX SHEET MUST BE SIGNED, DATED AND SEALED BY |
| THOSE PROFESSIONAL ENGINEERS IN RESPONSIBLE CHARGE OF |
| THE PRODUCTION AND PREPARATION OF EACH SECTION OF THE |
| ENGINEERING SPECIFICATIONS OR CALCULATIONS, WITH |
| SUFFICIENT INFORMATION ON THE INDEX SHEET SO THAT THE |
| USER WILL BE AWARE OF EACH PORTION OF THE |
| SPECIFICATIONS OR CALCULATIONS FOR WHICH EACH |
| PROFESSIONAL ENGINEER IS RESPONSIBLE. |
| 2. THE INDEX SHEET SHALL INCLUDE AT A MINIMUM: |
| A. THE PRINTED NAME, ADDRESS AND LICENSE NUMBER OF EACH |
| ENGINEER IN RESPONSIBLE CHARGE OF THE PRODUCTION OF ANY |
| PORTION OF THE CALCULATIONS OR SPECIFICATIONS. |
| B. IF THE ENGINEER SIGNING, DATING AND SEALING |
| CALCULATIONS OR SPECIFICATIONS IS PRACTICING THROUGH A |
| DULY QUALIFIED ENGINEERING BUSINESS ORGANIZATION; THE |
| PRINTED NAME AND ADDRESS OF THE QUALIFIED ENGINEERING |
| BUSINESS ORGANIZATION. |
| C. IDENTIFICATION OF THE PROJECT, BY ADDRESS OR BY LOT |
| NUMBER, BLOCK NUMBER, SECTION OR SUBDIVISION AND CITY |
| OR COUNTY. |
| D. IDENTIFICATION OF THE APPLICABLE BUILDING CODE AND |
| CHAPTER(S) AND FLORIDA FIRE PREVENTION CODE, WHEN |
| APPLICABLE, THAT THE DESIGN IS INTENDED TO MEET. |
| E. IDENTIFICATION OF ANY COMPUTER PROGRAM USED FOR |
| ENGINEERING THE SPECIFICATIONS OR CALCULATIONS. |
| (C) ENGINEERING REPORTS OR OTHER DOCUMENTS. |
| 1. A SIGNATURE PAGE OR COVER LETTER SHALL BE USED AND |
| SHALL BE SIGNED, DATED AND SEALED BY EACH PROFESSIONAL |
| ENGINEER WHO IS IN RESPONSIBLE CHARGE OF ANY PORTION OF |
| THE REPORT WITH SUFFICIENT INFORMATION PROVIDED SO THAT |
| THE USER WILL BE AWARE OF EACH PORTION FOR WHICH EACH |
| PROFESSIONAL ENGINEER IS RESPONSIBLE. |
| 2. IF THE ENGINEER SIGNING, DATING AND SEALING AN |
| ENGINEERING REPORT OR OTHER DOCUMENT IS PRACTICING |
| THROUGH A DULY QUALIFIED ENGINEERING BUSINESS |
| ORGANIZATION, THE PRINTED NAME AND ADDRESS OF THE |
| QUALIFIED ENGINEERING BUSINESS ORGANIZATION. |
| (D) THE DATE THAT THE SIGNATURE AND SEAL IS AFFIXED AS |
| PROVIDED HEREIN SHALL BE ENTERED ON SAID PLANS, PRINTS, |
| SPECIFICATION, REPORTS OR OTHER DOCUMENTS IMMEDIATELY |
| ADJACENT TO THE SIGNATURE OF THE PROFESSIONAL ENGINEER. |
| |
| 7) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| CITY RE-SUBMITTAL FORM. |
| |
| |
| |