2021-01-14 15:35:23 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| MARSHAL, WITH THE FOLLOWING COMMENTS: |
| |
| FIRE HAS NO OBJECTION TO A FOUNDATION PERMIT; THE BELOW |
| COMMENTS ARE MORE RELATED TO THE OCCUPANCY |
| CLASSIFICATION AND IF A LIFE SAFETY REVIEW IS REQUIRED |
| UNDER THE FLORIDA FIRE PREVENTION CODE. |
| |
| 1) SHEET A000 - WITHIN THE SECTION TITLED DESIGN |
| PARAMETERS, THERE IS AN INDICATION OF FBC GROUP R-1 |
| TWO-STORY DUPLEX. |
| |
| FOR CLARIFICATION PURPOSES, PER THE FLORIDA FIRE |
| PREVENTION CODE ARE THESE CONSIDERED A TWO-FAMILY |
| DWELLING PER NFPA 101 CH 24....OR ARE THEY ASSOCIATED |
| WITH THE PROPOSED HOTEL AND BE RENTED OUT TO CLIENTS |
| THUS COMPLYING WITH CH 28. |
| |
| 3.3.145* HOTEL. A BUILDING OR GROUPS OF BUILDINGS UNDER |
| THE SAME |
| MANAGEMENT IN WHICH THERE ARE SLEEPING ACCOMMODATIONS |
| FOR MORE |
| THAN 16 PERSONS AND PRIMARILY USED BY TRANSIENTS FOR |
| LODGING WITH OR |
| WITHOUT MEALS. |
| |
| 28.1.1.5 THE TERM HOTEL, WHEREVER USED IN THIS CODE, |
| SHALL INCLUDE |
| A HOTEL, AN INN, A CLUB, A MOTEL, A BED AND BREAKFAST, |
| OR ANY OTHER |
| STRUCTURE MEETING THE DEFINITION OF HOTEL. |
| |
| PLEASE PROVIDE SPECIFIC DETAILS. |
| |
| |
| |
| 2) SHOULD THIS BE CLASSIFIED AS AHOTEL OCCUPANCY A FIRE |
| SPRINKLER SYTEM IS REQUIRED. |
| |
| 28.3.5 EXTINGUISHMENT REQUIREMENTS. |
| 28.3.5.1 ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT BY |
| AN |
| APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN |
| ACCORDANCE |
| WITH 28.3.5.3. |
| |
| PLEASE PROVIDE SPECIFIC DETAILS AND EOR DOCUMENTS PER |
| F.A.C. 69G WITH THIS MASTER |
| |
| |
| |
| 3) SHOULD THIS BE CLASSIFIED AS AHOTEL OCCUPANCY A FIRE |
| ALARM SYTEM IS REQUIRED. |
| |
| 28.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. |
| 28.3.4.1 GENERAL. A FIRE ALARM SYSTEM IN ACCORDANCE |
| WITH SECTION |
| 9.6, EXCEPT AS MODIFIED BY 28.3.4.2 THROUGH 28.3.4.6, |
| SHALL BE |
| PROVIDED. |
| |
| PLEASE PROVIDE SPECIFIC DETAILS WITH THIS MASTER. |
| |
| |
| 4) SHOULD THIS BE CLASSIFIED AS A HOTEL OCCUPANCY AND |
| WITH AN ATTACHED GARAGE |
| |
| 28.3.4.6 CARBON MONOXIDE ALARMS AND CARBON MONOXIDE |
| DETECTION SYSTEMS. |
| 28.3.4.6.1 CARBON MONOXIDE ALARMS OR CARBON MONOXIDE |
| DETECTORS |
| IN ACCORDANCE WITH SECTION 9.8 AND 28.3.4.6 SHALL BE |
| PROVIDED IN |
| NEW HOTELS AND DORMITORIES WHERE EITHER OF THE |
| FOLLOWING |
| CONDITIONS EXISTS: |
| (1) GUEST ROOMS OR GUEST SUITES WITH COMMUNICATING |
| ATTACHED |
| GARAGES, UNLESS OTHERWISE EXEMPTED BY 28.3.4.6.3 |
| (2) GUEST ROOMS OR GUEST SUITES CONTAINING A |
| PERMANENTLY |
| INSTALLED FUEL-BURNING APPLIANCE OR FUEL-BURNING |
| FIREPLACE |
| |
| PLEASE PROVIDE SPECIFIC DETAILS WITH THIS MASTER. |
| |
| |
| |
| 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET |
| REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE |
| ABOVE. |
| |
| |
| |
| 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| RE-SUBMITTAL OF THE ABOVE. |
| |
| |