Date |
Text |
2021-01-06 14:14:35 | 01/06/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS |
| |
| NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| |
| 1. THE CITY OF WEST PALM BEACH HAS NO RECORD OF ANY |
| PERMITS THAT PERTAIN TO EXISTING PLUMBING OR GAS AT |
| THIS ADDRESS. IN A CONVERSATION WITH THE BUILDING |
| OFFICIAL, HE SAID THAT HE HAS SPOKEN WITH THE OWNER OF |
| THIS STRUCTURE, AND HE AND I DISCUSSED THE VIOLATION. |
| IT WAS NOTED THAT THIS WOULD BE TURNED BACK INTO A |
| SINGLE-FAMILY HOUSE. PLEASE SHOW AND PUT A NARRATIVE ON |
| THE PLANS OF THE SCOPE OF WORK. ANY PLUMBING THAT IS |
| GOING TO RETURN TO ITS ORIGINAL STATE WILL HAVE TO BE |
| DOCUMENTED. THE FIELD INSPECTOR MAY FIND OTHER |
| VIOLATIONS, AND IN THIS REVIEW, THE EXAMINED VIOLATIONS |
| FOR THIS REVIEW WILL NEED TO BE ADDRESSED. |
| |
| 2. PLEASE REFER TO ANY PLUMBING APERTURES AS NEW, NOT |
| EXISTING, AS THERE WAS NEVER PERMITTED IN THE FORM OF A |
| PERMIT FOR THEM PER THE WPB AMENDMENTS TO THE FBC |
| SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| 3. THERE SEEM TO BE OTHER DRAWINGS, 01, 02, AND 03, |
| SECTIONS OF THE FLOOR PLANS WITH NOTES AND WATER LINE |
| AND NOT SIGNED OR SEALED BY THE ENGINEER OF RECORD IN |
| ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE |
| 61G10-11.010 SEALS. |
| |
| 4. SIGNED AND SEALED DRAWINGS NEED TO BE |
| DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR |
| ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW - OR - |
| IF YOUR ENGINEER DOES NOT HAVE AN ELECTRONIC OR DIGITAL |
| SIGNATURE - PLEASE DROP OFF (CITY HALL DROPBOX) THE |
| ORIGINAL SIGNED AND SEALED DOCUMENT ALONG WITH A "PLAN |
| REVIEW REQUEST FORM" EXPLAINING THE REASON FOR |
| SUBMITTING THE DOCUMENT OR DRAWINGS. THE PLAN REVIEW |
| REQUEST FORM CAN BE OBTAINED BY EMAILING [email protected] AND |
| ASKING FOR THE FORM. |
| |
| 5. THE PLANS SUBMITTED STATE AN EXISTING GAS HEATER, |
| BUT THE CITY OF WEST PALM BEACH DOES NOT HAVE ANY |
| RECORD OF PERMIT OR INSPECTIONS ON THE GAS HEATER. THIS |
| IS UP TO THE HOMEOWNER TO MAKE AN APPLICATION TO THE |
| BUILDING OFFICIAL AND OBTAIN THE REQUIRED PERMIT PER |
| THE WPB AMENDMENTS TO THE FBC SEC. 105.1. |
| 6. A SUB GAS PERMIT IS REQUIRED BY A LICENSED |
| CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS |
| TO THE FBC SEC. 105.1. PLEASE REFER TO THE COMMENTS ON |
| THE GAS. |
| |
| 7. PLEASE PROVIDE A DETAILED WORK SCOPE ON SHEET 1-1 |
| AND REFER TO COMMENT TWO AND SUBMITTED SCOPE OF WORK |
| PER THE WPB AMENDMENTS TO THE FBC SEC. 107.2.1. |
| INFORMATION ON CONSTRUCTION. |
| |
| 8. THE WASHING MACHINE IS OUTSIDE THE RESIDENTIAL |
| STRUCTURE, AND PER MANUFACTURER SPECIFICATION, THEY ARE |
| NOT MADE FOR OUTSIDE USE. ARE THEY IN A STRUCTURE, AND |
| IS THE STRUCTURE APPROVED? PLEASE FIND A LOCATION |
| INSIDE THE HOUSE OR PROVIDE AN ENGINEERED STRUCTURE |
| WITH A WIND LOAD CALCULATION ACCORDING TO PER THE 2017 |
| FLORIDA RESIDENTIAL CODE. |
| |
| 9. HOT WATER LINES NOT IN CONDITION SPACE NEED TO BE |
| INSULATED WITH A MINIMUM R-3 PER THE 2017 FBC SEC. RE |
| 403.5.3. |
| |
| WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA |
| |
| LUIS A. CRESPO |
| PLUMBING PLAN EXAMINER / INSPECTOR |
| EMAIL: [email protected] OFFICE: 561 805-6720 |
| |