Plan Review Notes
Plan Review Notes For Permit 20121326
Permit Number 20121326
Review Stop B
Sequence Number 3
Notes
Date Text
2021-04-12 12:26:24NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20121326
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY. CONTRACTOR TO
 ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME OR
 IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 IMPORTANT:
 ENERGY CALCULATIONS MUST BE SIGNED BY THE OWNER/AGENT
 PRIOR TO ISSUING PERMIT.
  
  
  
 ORIGINAL COMMENT:
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5.1 FBC-ENERGY CONSERVATION.
  
 THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED AND
 DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY
 DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS
 REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION,
 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 A)ENERGY CALCULATIONS SUBMITTED WERE NOT SIGNED AND
 DATED BY THE OWNER OR LEGAL AGENT AS REQUESTED ON THE
 FIRST REVIEW. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION
  
 REPEAT COMMENT. NOT ADDRESSED.
 B)FORM SUBMITTED R405-2020 IS FOR THE 2020 FBC EDITION.
 THIS PERMIT APPLICATION AND PLANS WERE REVIEWED UNDER
 THE 2017 FBC. NEED TO REVISE AND RESUBMIT FORM BASED ON
 THE 2017 FBC.
 CHAPTER 553 F.S.
  
 REPEAT COMMENT. NOT ADDRESSED.
 C)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. OWNER INFORMATION IS INCORRECT. PROVIDE BUILDER'S
 NAME.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 D)ITEM #2 ON PAGE 1 OF 5 IS INCORRECT. SEE QUESTION AND
 REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 E)ITEM #10 ON PAGE 1 OF 5 DOESN'T MATCH PLANS. SEE
 INSULATION NOTES ON SHEET A.1.1 AND REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 F)ITEM #11 ON PAGE 1 OF 5 DOESN'T MATCH PLANS. SEE
 INSULATION NOTES ON SHEET A.1.1 AND REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 G)ROOF TYPE ON PAGE 2 OF 5 IS INCOMPLETE. THERE ARE
 MORE ROOF TYPES IN THIS HOUSE. SEE PLANS AND REVISE AS
 REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 H)WINDOWS INFORMATION ON PAGE 4 OF 5 IS INCORRECT. SEE
 PLANS AND REVISE WINDOW ORIENTATION, WINDOW AREA,
 WINDOW OVERHANG DEPTH AND SEPARATION.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 REPEAT COMMENT. NOT ADDRESSED.
 I)BUILDER TO COMPLETE AND SIGN THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
  
 2- OK.
 3- OK
 4- OK
 5- OK
  
 6-SHEET A.1:
 A)OK
 B)OK
  
 C) GROUND FLOOR ON SHEET A.1 SHOWS A PREFABRICATED
 PULL-DOWN ACCESS LADDER (22-1/2" X 54"). SPECIFY THE
 ADDITIONAL ATTIC LIVE LOADS AS REQUIRED BY TABLE R301.5
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 INFORMATION REGARDING THE ADDITIONAL ATTIC LIVE LOAD
 FOR STORAGE AS REQUIRED BY TABLE R301.5 WAS NOT
 PROVIDED.
  
 7- OK
  
 8- PROVISO: TO BE SUBMITTED LATER AS DEFERRED
 SUBMITTAL.
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL):
  
 A)OVERHEAD GARAGE DOOR.
 B)METAL ROOFING.
 C)ALL WINDOW TYPES SHOWN ON PLANS AND WINDOW SCHEDULES.
 D)ENTRY DOOR IF DIFFERENT THAN ALL OTHER EXTERIOR
 DOORS.
 E)OVERHEAD GARAGE DOOR
  
 9- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 PRODUCT APPROVALS ALREADY SUBMITTED WERE NOT
 REVIEWED/APPROVED BY THE ARCHITECT OF RECORD. EITHER
 REVIEW AND APPROVED THOSE PRODUCT APPROVALS THAT WERE
 ALREADY SUBMITTED OR ALL THE PRODUCT APPROVALS CAN BE
 SUBMITTED AS DEFERRED SUBMITTAL AFTER THE PERMIT IS
 ISSUED TO AVOID CONFLICT/DELAYS. SEE PROVISO ON ITEM #8
 ABOVE.
  
 10- PROVISO:
 HOUSE IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT IS
 SPECIFYING R-30 SPRAY INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE FOAM INSULATION TO VERIFY
 COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 11- DEFERRED SUBMITTAL:
 A)PROVIDE GLAZED RAILINGS SHOP DRAWINGS (REVIEWED BY
 ARCHITECT OF RECORD). NOTE: TABLE R301.5
 FBC-RESIDENTIAL. NEED A SAFETY FACTOR OF 4. SEE NOTE
 "H".
  
 B)BALCONY CABLE RAILINGS SHOP DRAWINGS (REVIEWED BY
 ARCHITECT OF RECORD).
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]