Plan Review Notes
Plan Review Notes For Permit 20121077
Permit Number 20121077
Review Stop B
Sequence Number 3
Notes
Date Text
2021-10-21 15:18:16NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20121077
  
 NOTE:
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORRCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
 ORIGINAL COMMENT:
 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 RESPONSE:
 A) PROVIDE DIMENSIONS ON TYPICAL WET SWALE CROSS
 SECTION. SPECIFY DEPTH OF SWALE, DISTANCE FROM
 BUILDING, ETC. SEC. 1072.1 CITY AMENDMENTS.
 B) PROVIDE TRENCH WITH GRAVEL DETAIL #1 AS SHOWN ON
 DRAINAGE PLAN ALONG PERIMETER OF LOT. DETAIL WAS NOT
 GIVEN. SEC. 107.2.1 CITY AMENDMENTS.
  
  
 ORIGINAL COMMENT:
 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING
 COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL.
  
 RESPONSE:
 BASED ON THE ROOF FRAMING PLAN, THE LOCATION OF THE
 ATTIC ACCESS DOESN'T PROVIDE THE CLEARANCE REQUIRED BY
 SEC. R807 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM.
 IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4.
 REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 RESPONSE:
 REVISED ROOF FRAMING PLAN IS INCOMPLETE. IT IS MISSING
 THE ROOF AT THE ENTRY PORCH. THERE IS NOT CORRELATION
 BETWEEN THE WOOD BEAM SCHEDULES AND THE ROOF FRAMING
 PLAN. THERE IS NOT TRUSS CONNECTOR SCHEDULE. THERE IS
 NOT INFORMATION ABOUT THE GABLE END BEAMS. ARE THESE
 CONCRETE RAKED BEAMS?. THERE IS NOT INFORMATION FOR
 PORCH BEAMS, COLUMNS, ALL STRUCTURAL CONNECTORS OF ALL
 STRUCTURAL MEMBERS (ROOF TRUSSES, BEAMS AND COLUMNS).
 NEW ROOF FRAMING PLAN SHOWS TWO GABLE END ROOFS
 INTERSECTING ON THE REAR OF THE HOUSE. SEE REAR
 ELEVATION ON SHEET A-2. NEED TO PROVIDE DETAILS AND
 SPECIFICATIONS FOR CRICKET CONSTRUCTION IN THIS AREA.
 NEED TO PROVIDE COMPLETE ROOF FRAMING PLAN WITH ALL THE
 INFORMATION. SEC. R301.1 FBC-RESIDENTIAL.
  
 ORIGINAL COMMENT:
 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF
 SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING
 FASTENING AS REQUIRED BY SEC. R803.2.3.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 ENGINEER'S RESPONSE SAID SEE REVISED SHEET S-3.
 SECTIONS 1 AND 2 ON SHEET S-3 DON'T MATCH REVISED ROOF
 FRAMING PLAN. SEE NEW ROOF PROFILE. THERE ARE NO
 SPECIFICATIONS FOR THE ROOF SHEATHING. PORCH
 CONSTRUCTION DOESN'T MATCH PORCH SHOWN ON THE EXTERIOR
 ELEVATIONS AND NEEDS MORE INFORMATION. FRAMING AT GABLE
 ENDS IS NOT CLEAR. HOW THE GABLE END IS GOING TO BE
 BUILT. SPECIFY ALL GABLE FRAMING MEMBERS AND
 CONNECTORS. NEED COLUMNS CONNECTOR AT TOP AND BOTTOM,
 WOOD BEAM SHOWN DON'T REFLECT (2)2X12 WOOD BEAM. DETAIL
 SHOWS FOUR 2X12'S. SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: ENGINEER OF RECORD TO COORDINATE ALL PLANS,
 DETAILS AND SPECIFICATIONS TO AVOID MORE CONFLICTS AND
 DELAYS.
  
 ORIGINAL COMMENT:
 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND
 BOTTOM CONNECTORS AND FURRING DETAILS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. SEE RESPONSE TO ITEM #6 ABOVE.
  
 ORIGINAL COMMENT:
 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
  
 ORIGINAL COMMENT:
 A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS.
  
 RESPONSE:
 NOA 19-0617.05 SUBMITTED NOW IS NOT FOR SHINGLES. WRONG
 NOA AGAIN.
  
 ORIGINAL COMMENT:
 D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A
 PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE
 FLORIDA PRODUCT APPROVAL.
  
 RESPONSE:
 NOA 20-0730.05 SUBMITTED IS FOR INSTALLATION TO WOOD
 FRAMED BUILDINGS. THIS HOUSE IS CONCRETE BLOCK. NEED
 PRODUCT APPROVAL FOR INSTALLATION ON CONCRETE BLOCK
 CONSTRUCTION.
  
 E) SINGLE HUNG WINDOWS. NEW COMMENT BASED ON REVISED
 PLANS. PROVIDE PRODUCT APPROVAL FOR SINGLE HUNG WINDOW
 SIZE SPECIFIED ON PLANS FO WINDOW A. NEW 72"W X 52"H
 SINGLE HUNG WINDOW.
  
 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS
 (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION
 THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY
 AMENDMENTS.
  
 RESPONSE:
 REVISE NEW TYPICAL WALL SECTION ON SHEET A1:
 A) FOOTING SIZE DOESN'T MATCH SIZE SPECIFIED ON THE
 FOUNDATION PLAN. SEC. 107.2.1 CITY AMENDMENTS.
  
 B)ROOFING COVER AND UNDERLAYMENT SPECIFIED IS NOT
 CLEAR. THESE SPECIFICATIONS ARE NOT FOR SHINGLES.
 COORDINATE WITH PRODUCT APPROVAL COMMENT ABOVE. SEC.
 107.2.1 CITY AMENDMENTS.
  
 C)ROOF SHEATHING NAILING SPECIFICATIONS ARE NOT CLEAR.
 COORDINATE WITH ITEM #7 ABOVE. NOTE: SEE TABLE
 R803.2.3.1 FBC-RESIDENTIAL FOR MINIMUM ROOF SHEATHING
 ATTACHMENT.
  
 NEW COMMENTS:
 16- FOUNDATION PLAN ON SHEET S1:
 A)MISSING THE FOOTING FOR THE FRONT AND REAR PORCHES.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 B)FOUNDATION PLANS DOESN'T SHOW THE FOOTINGS SHOWN ON
 THE FOOTING SCHEDULE. SEC. 107.2.1 CITY AMENDMENTS.
  
 C) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF FRONT AND REAR STAIRWAYS SHOWING
 COMPLIANCE WITH SEC. R311.7 FBC-RESIDENTIAL.
  
 17- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE FRONT AND BACK GUARDRAILS SHOWING
 COMPLIANCE WITH SEC. R312.1 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]