Plan Review Notes
Plan Review Notes For Permit 20121077
Permit Number 20121077
Review Stop B
Sequence Number 2
Notes
Date Text
2021-08-17 13:10:40NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
 PERMIT #20121077
  
 NOTE:
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
  
  
 ORIGINAL COMMENT:
 1-ENERGY CALCULATIONS SUBMITTED:
 A) THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR
 OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER
 SHALL CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH
 THE CODE, AS PER SECTION 553.907, FLORIDA STATUTES,
 PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 B) PROVIDE THE NAME OF THE PERSON DOING THE
 CALCULATIONS AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 C)PROVIDE CORRECT AND COMPLETE INFORMATION ON TOP OF
 FORM. CORRECT ADDRESS IS 839 4TH STREET NOT 837 4TH
 STREET. PROVIDE OWNER'S NAME. PROVIDE BUILDER'S NAME.
 PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH.
 REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 D)ITEM #8(A) ON PAGE 1 OF 4 SPECIFIES R-5 SLAB-ON-GRADE
 EDGE INSULATION. PLANS DON'T SPECIFY ANY SLAB EDGE
 INSULATION. REVISE AS REQUIRED TO MATCH.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 E)ITEM #9(A) ON PAGE 1 OF 4 SPECIFIES R-4.5 EXTERIOR
 INSULATION ON CONCRETE BLOCK. PLANS DON'T SPECIFY
 EXTERIOR INSULATION ON THE CONCRETE BLOCK. THE
 INSULATION IS ON THE INTERIOR SIDE. SEE PLANS AND
 REVISE AS REQUIRED TO MATCH, INCLUDING R-VALUE
 SPECIFIED.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 F)ITEM #10(A) ON PAGE 1 OF 4 SPECIFIES R-19 UNDER ATTIC
 INSULATION. THIS DOESN'T MATCH PLANS. SEE PLANS AND
 REVISE AS REQUIRED TO MATCH, INCLUDING.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 G)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 NEEDS TO BE
 COORDINATED WITH PLANS. PLANS ARE NOT CLEAR ON WHAT
 ROOFING MATERIAL IS GOING TO BE INSTALLED BUT IT
 DOESN'T SPECIFY FLAT TILE OR SLATE. COORDINATE WITH
 ENGINEER PLANS AND REVISE AS REQUIRED TO MATCH.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 H)REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. PLANS
 DON'T SHOW ANY 1/300 VENT RATIO. TYPICALLY, THE RATIO
 IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. OR
 PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE
 COMPLETE DETAILS/SPECIFICATIONS SHOWING COMPLIANCE WITH
 THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC.
 R806.2. NOTE: ENGINEER OF RECORD NEEDS TO
 REVIEW/APPROVE THEM PRIOR TO SUBMITTAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 I)DOOR TYPE INFORMATION SPECIFIED ON PAGE 3 OF 4 IS
 INCORRECT. ACCORDING TO PLANS AND PRODUCT APPROVALS
 SUBMITTED THE ENTRY DOOR AND THE BEDROOM #3 DOORS ARE
 ALUMINUM DOORS WITH GLAZING. GLASS IN THESE DOORS NEED
 TO BE INCLUDED ON THE GLASS CALCULATIONS AS REQUIRED BY
 SEC. R405.5.3.1 AND SEC. R405.5.3.3 FBC-ENERGY
 CONSERVATION. REVISE AS REQUIRED.
  
 RESPONSE:
 REPEAT COMMENT.
  
 J)WINDOWS INFORMATION SPECIFIED ON 3 OF 4 DOESN'T MATCH
 PLANS. REVISE THE WINDOW AREA AND WINDOW OVERHANG DEPTH
 AND SEPARATION TO MATCH PLANS.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT.
  
 NEW COMMENT:
 K)FLOOR PLAN WAS REVISED. NEW ENERGY CALCULATIONS NEED
 TO BE DONE BASED ON THE NEW FLOOR PLAN. COORDINATE ALL
 THE INFORMATION ACCORDINGLY.
  
 ORIGINAL COMMENT:
 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING:
 R401.3 FBC-RESIDENTIAL.
 SEC. 107.2.5 CITY AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING
 COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 4-PLANS SUBMITTED DON'T SPECIFY WHAT IS THE ROOFING
 MATERIAL. IS IT SHINGLES?, TILE?. IF USING SHINGLES ,
 THEN A ROOF PITCH OF 2:12 TO LESS THAN 4:12 REQUIRES
 TWO LAYERS OF UNDERLAYMENT AS REQUIRED BY SEC. R905.2.2
 FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS ON PLANS FOR
 THE TWO LAYERS OF UNDERLAYMENT. ALSO, PROVIDE
 SPECIFICATIONS FOR THE FLAT ROOF.
  
 RESPONSE:
 PLANS SUBMITTED STILL DON'T SPECIFY THE ROOF PITCH.
 SPECIFY THE ROOF SLOPE ON ALL ROOF AREAS SHOWN ON THE
 REVISED PLANS.
  
  
 5- OK. NO FLAT ROOFS ON REVISED PLANS.
  
 ORIGINAL COMMENT:
 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM.
 IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4.
 REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 RESPONSE:
 ARCHITECTURAL PLANS WERE REVISED. NEW FLOOR
 PLANS/ELEVATIONS WERE SUBMITTED BUT NONE OF THE
 STRUCTURAL PLANS WERE REVISED. REVISE ALL STRUCTURAL
 PLANS AND COORDINATE ACCORDINGLY.
  
 ORIGINAL COMMENT:
 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF
 SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING
 FASTENING AS REQUIRED BY SEC. R803.2.3.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND
 BOTTOM CONNECTORS AND FURRING DETAILS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 10- REVISE THE ADDRESS INFORMATION ON ALL DRAWINGS,
 CALCULATIONS, ENERGY CALCULATIONS, ETC. SUBMITTED TO
 AVOID CONFLICTS/DELAYS. THERE ARE TWO STRUCTURES IN
 THIS LOT. 839 4TH STREET IS THE ADDRESS FOR THE REAR
 STRUCTURE. THIS PERMIT APPLICATION IS FOR THE REAR
 STRUCTURE ONLY. 837 4TH STREET IS THE MAIN HOUSE. THIS
 WILL FACILITATE INSPECTIONS AND RECORDS KEEPING.
 SEC. 107.2.1.3 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT.
  
 ORIGINAL COMMENT:
 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR
  
 A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS.
  
 RESPONSE:
 NOA 19-0313.03 SUBMITTED IS FOR FLAT ROOFS OVER
 LIGHTWEIGHT CONCRETE DECKS. THIS IS INCORRECT. PROVIDE
 CORRECT SHINGLES PRODUCT APPROVAL.
  
 B)OK. REVISED PLANS DON'T SHOW FLAT ROOFS NOW.
  
 C)SINGLE HUNG WINDOWS A SPECIFIED ON REVISED PLANS.
  
 D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A
 PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE
 FLORIDA PRODUCT APPROVAL.
  
 NOTE: CLARIFY WHY SUBMITTING PRODUCT APPROVAL FOR
 HORIZONTAL SLIDER WINDOWS IF THEY ARE NOT SPECIFIED ON
 THE REVISED PLANS?
  
 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS
 (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC.
 107.3.4.1 CITY AMENDMENTS.
  
 NEW COMMENTS BASED ON REVISED PLANS.
 13- SINGLE HUNG WINDOW SIZE SPECIFIED FOR BEDROOM #3
 DOESN'T COMPLY WITH THE MINIMUM CLEAR OPENING HEIGHT
 REQUIRED BY SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
  
 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION
 THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY
 AMENDMENTS.
  
 15- REVISED ELEVATIONS SHOW WHAT LOOKS LIKE CRAWL SPACE
 VENTILATION. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS. NOTE: STRUCTURAL PLANS WERE NOT
 REVISED. IT IS NOT KNOW IF THE FLOOR IS GOING TO BE
 WOOD OR CONCRETE SLAB.
 CRAWL SPACE VENTILATION WITH FLOOR JOISTS NEED TO
 COMPLY WITH SEC. R409 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]