2021-08-17 13:10:40 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| PERMIT #20121077 |
| |
| NOTE: |
| ARCHITECTS-ENGINEERS |
| FLORIDA STATUTE 553.80(2)(B): |
| ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN |
| PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT |
| NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE |
| FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT |
| DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE |
| TIMES FOR FAILURE TO CORRECT A CODE VIOLATION |
| SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, |
| INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, |
| STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, |
| VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS |
| SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF |
| THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO |
| CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH |
| TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED |
| FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT |
| OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS |
| REVIEW |
| |
| |
| |
| ORIGINAL COMMENT: |
| 1-ENERGY CALCULATIONS SUBMITTED: |
| A) THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR |
| OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER |
| SHALL CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH |
| THE CODE, AS PER SECTION 553.907, FLORIDA STATUTES, |
| PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR |
| RENOVATION AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY |
| CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| B) PROVIDE THE NAME OF THE PERSON DOING THE |
| CALCULATIONS AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY |
| CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| C)PROVIDE CORRECT AND COMPLETE INFORMATION ON TOP OF |
| FORM. CORRECT ADDRESS IS 839 4TH STREET NOT 837 4TH |
| STREET. PROVIDE OWNER'S NAME. PROVIDE BUILDER'S NAME. |
| PERMITTING OFFICE IS WEST PALM BEACH NOT PALM BEACH. |
| REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY |
| CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| D)ITEM #8(A) ON PAGE 1 OF 4 SPECIFIES R-5 SLAB-ON-GRADE |
| EDGE INSULATION. PLANS DON'T SPECIFY ANY SLAB EDGE |
| INSULATION. REVISE AS REQUIRED TO MATCH. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| E)ITEM #9(A) ON PAGE 1 OF 4 SPECIFIES R-4.5 EXTERIOR |
| INSULATION ON CONCRETE BLOCK. PLANS DON'T SPECIFY |
| EXTERIOR INSULATION ON THE CONCRETE BLOCK. THE |
| INSULATION IS ON THE INTERIOR SIDE. SEE PLANS AND |
| REVISE AS REQUIRED TO MATCH, INCLUDING R-VALUE |
| SPECIFIED. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| F)ITEM #10(A) ON PAGE 1 OF 4 SPECIFIES R-19 UNDER ATTIC |
| INSULATION. THIS DOESN'T MATCH PLANS. SEE PLANS AND |
| REVISE AS REQUIRED TO MATCH, INCLUDING. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| G)ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 NEEDS TO BE |
| COORDINATED WITH PLANS. PLANS ARE NOT CLEAR ON WHAT |
| ROOFING MATERIAL IS GOING TO BE INSTALLED BUT IT |
| DOESN'T SPECIFY FLAT TILE OR SLATE. COORDINATE WITH |
| ENGINEER PLANS AND REVISE AS REQUIRED TO MATCH. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| H)REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. PLANS |
| DON'T SHOW ANY 1/300 VENT RATIO. TYPICALLY, THE RATIO |
| IS 1/150 NOT 1/300. SEC. R806.2 FBC-RESIDENTIAL. OR |
| PERSON PREPARING THE ENERGY CALCULATIONS TO PROVIDE |
| COMPLETE DETAILS/SPECIFICATIONS SHOWING COMPLIANCE WITH |
| THE 1/300 RATIO AS REQUIRED BY THE EXCEPTION ON SEC. |
| R806.2. NOTE: ENGINEER OF RECORD NEEDS TO |
| REVIEW/APPROVE THEM PRIOR TO SUBMITTAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| I)DOOR TYPE INFORMATION SPECIFIED ON PAGE 3 OF 4 IS |
| INCORRECT. ACCORDING TO PLANS AND PRODUCT APPROVALS |
| SUBMITTED THE ENTRY DOOR AND THE BEDROOM #3 DOORS ARE |
| ALUMINUM DOORS WITH GLAZING. GLASS IN THESE DOORS NEED |
| TO BE INCLUDED ON THE GLASS CALCULATIONS AS REQUIRED BY |
| SEC. R405.5.3.1 AND SEC. R405.5.3.3 FBC-ENERGY |
| CONSERVATION. REVISE AS REQUIRED. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| J)WINDOWS INFORMATION SPECIFIED ON 3 OF 4 DOESN'T MATCH |
| PLANS. REVISE THE WINDOW AREA AND WINDOW OVERHANG DEPTH |
| AND SEPARATION TO MATCH PLANS. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| NEW COMMENT: |
| K)FLOOR PLAN WAS REVISED. NEW ENERGY CALCULATIONS NEED |
| TO BE DONE BASED ON THE NEW FLOOR PLAN. COORDINATE ALL |
| THE INFORMATION ACCORDINGLY. |
| |
| ORIGINAL COMMENT: |
| 2-PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE |
| FOLLOWING: |
| R401.3 FBC-RESIDENTIAL. |
| SEC. 107.2.5 CITY AMENDMENTS. |
| SEC. 110.9 CITY AMENDMENTS. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 3-SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING |
| COMPLIANCE WITH SEC. R807 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 4-PLANS SUBMITTED DON'T SPECIFY WHAT IS THE ROOFING |
| MATERIAL. IS IT SHINGLES?, TILE?. IF USING SHINGLES , |
| THEN A ROOF PITCH OF 2:12 TO LESS THAN 4:12 REQUIRES |
| TWO LAYERS OF UNDERLAYMENT AS REQUIRED BY SEC. R905.2.2 |
| FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS ON PLANS FOR |
| THE TWO LAYERS OF UNDERLAYMENT. ALSO, PROVIDE |
| SPECIFICATIONS FOR THE FLAT ROOF. |
| |
| RESPONSE: |
| PLANS SUBMITTED STILL DON'T SPECIFY THE ROOF PITCH. |
| SPECIFY THE ROOF SLOPE ON ALL ROOF AREAS SHOWN ON THE |
| REVISED PLANS. |
| |
| |
| 5- OK. NO FLAT ROOFS ON REVISED PLANS. |
| |
| ORIGINAL COMMENT: |
| 6- BEAM SCHEDULE ON SHEET S-2 ONLY SPECIFIES B-1 BEAM. |
| IT DOESN'T SPECIFY THE RAKE BEAM SHOWN ON SHEET S-4. |
| REVISE AS REQUIRED TO CLARIFY. SEC. 107.2.1 CITY |
| AMENDMENTS. |
| |
| RESPONSE: |
| ARCHITECTURAL PLANS WERE REVISED. NEW FLOOR |
| PLANS/ELEVATIONS WERE SUBMITTED BUT NONE OF THE |
| STRUCTURAL PLANS WERE REVISED. REVISE ALL STRUCTURAL |
| PLANS AND COORDINATE ACCORDINGLY. |
| |
| ORIGINAL COMMENT: |
| 7- PLANS DON'T PROVIDE SPECIFICATIONS FOR THE ROOF |
| SHEATHING. SPECIFY TYPE, THICKNESS AND ROOF SHEATHING |
| FASTENING AS REQUIRED BY SEC. R803.2.3.1 |
| FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR |
| STEEL COLUMNS SHOWN ON THE FRONT PORCH. SPECIFY TOP AND |
| BOTTOM CONNECTORS AND FURRING DETAILS. |
| SEC. R301.1 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 9- PROVIDE DOORS AND WINDOWS STRUCTURAL BUCK DETAIL. |
| NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO |
| THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 |
| FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 10- REVISE THE ADDRESS INFORMATION ON ALL DRAWINGS, |
| CALCULATIONS, ENERGY CALCULATIONS, ETC. SUBMITTED TO |
| AVOID CONFLICTS/DELAYS. THERE ARE TWO STRUCTURES IN |
| THIS LOT. 839 4TH STREET IS THE ADDRESS FOR THE REAR |
| STRUCTURE. THIS PERMIT APPLICATION IS FOR THE REAR |
| STRUCTURE ONLY. 837 4TH STREET IS THE MAIN HOUSE. THIS |
| WILL FACILITATE INSPECTIONS AND RECORDS KEEPING. |
| SEC. 107.2.1.3 CITY AMENDMENTS. |
| |
| RESPONSE: |
| REPEAT COMMENT. |
| |
| ORIGINAL COMMENT: |
| 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| 61G20-3.001 FOR |
| |
| A)ROOF MATERIAL FOR PITCHED ROOF AS SPECIFIED ON PLANS. |
| |
| RESPONSE: |
| NOA 19-0313.03 SUBMITTED IS FOR FLAT ROOFS OVER |
| LIGHTWEIGHT CONCRETE DECKS. THIS IS INCORRECT. PROVIDE |
| CORRECT SHINGLES PRODUCT APPROVAL. |
| |
| B)OK. REVISED PLANS DON'T SHOW FLAT ROOFS NOW. |
| |
| C)SINGLE HUNG WINDOWS A SPECIFIED ON REVISED PLANS. |
| |
| D)HARDIEBOARD SIDING. INFORMATION SUBMITTED IS NOT A |
| PRODUCT APPROVAL. NEED MIAMI DADE NOA OR COMPLETE |
| FLORIDA PRODUCT APPROVAL. |
| |
| NOTE: CLARIFY WHY SUBMITTING PRODUCT APPROVAL FOR |
| HORIZONTAL SLIDER WINDOWS IF THEY ARE NOT SPECIFIED ON |
| THE REVISED PLANS? |
| |
| 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS |
| (INCLUDING THE HARDIEBOARD SIDING) AS REQUIRED BY SEC. |
| 107.3.4.1 CITY AMENDMENTS. |
| |
| NEW COMMENTS BASED ON REVISED PLANS. |
| 13- SINGLE HUNG WINDOW SIZE SPECIFIED FOR BEDROOM #3 |
| DOESN'T COMPLY WITH THE MINIMUM CLEAR OPENING HEIGHT |
| REQUIRED BY SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS |
| REQUIRED. |
| |
| 14- PROVIDE COMPLETE WALL SECTION FROM FOUNDATION |
| THROUGH ROOF AS REQUIRED BY SEC. 107.5.3 CITY |
| AMENDMENTS. |
| |
| 15- REVISED ELEVATIONS SHOW WHAT LOOKS LIKE CRAWL SPACE |
| VENTILATION. PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS. NOTE: STRUCTURAL PLANS WERE NOT |
| REVISED. IT IS NOT KNOW IF THE FLOOR IS GOING TO BE |
| WOOD OR CONCRETE SLAB. |
| CRAWL SPACE VENTILATION WITH FLOOR JOISTS NEED TO |
| COMPLY WITH SEC. R409 FBC-RESIDENTIAL. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |