Plan Review Notes For Permit 20120803 |
Permit Number |
20120803 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2021-06-15 12:22:49 | NEW 8 STORY APT AND 6 STORY PARKING GARAGE | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE SHOW THE ACCESSIBLE SEATING AND COUNTER TOP | | ELEVATIONS AT THE BISTOR BAR AND DEMO. KITCHEN TO | | COMPLY WITH FBC ACCESSIBILITY FAIR HOUSING GUIDE LINES | | SECTION 5.GUIDELINES - REQUIREMENT 2 - NUMBER (12). | | 2) PLEASE SHOW THE FIRE RATING DETAILS FOR THE STEEL | | ANGLE SHOWN ON DETAIL DRAWING P/S-3.3 - FBC TABLE 601 | | 3) PLEASE SHOW THE FIRE RATING DETAILS FOR THE STEEL | | COLUMNS PER FBC TABLE 601 | | 4) PLEASE SHOW THE GARAGE AS OPEN OR ENCLOSED AND | | PROVIDE THE CALCULATIONS FOR THE OPEN GARAGE PER FBC | | 406.5.2 OR VENTILATION REQUIREMENTS FOR ENCLOSED GARAGE | | PER FBC 406.6.2 | | 5) DRAWING A-4.8 - THE FINISH SCHEDULE IS BLANK - | | PLEASE CORRECT. | | 6) PLEASE PROVIDE A SOIL REPORT AS NOTED ON THE | | DRAWINGS. ("SOIL REPORT HAS BEEN PROVIDED" 8/23/2021- | | COMMENT WILL BE REMOVED ON THE NEXT REVIEW) | | | | | | | | | | | | |
|