Plan Review Notes
Plan Review Notes For Permit 20120797
Permit Number 20120797
Review Stop HIST
Sequence Number 1
Notes
Date Text
2020-12-23 13:57:45THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. PROVIDE A PHOTO OF THE EXISTING DOORS TO BE REPLACED
 AND A GRAPHIC OF THE PROPOSED DOORS.
 2. ALL WINDOW REPLACEMENT WORK REQUIRES TO FOLLOW THE
 WINDOW PERMIT APPLICATION EXAMPLE. PLEASE EMAIL STAFF
 AT [email protected] TO REQUEST THE EXAMPLE. AT
 MINIMUM, STAFF NEEDS TO KNOW THE EXISTING WINDOWS AND
 THE PROPOSED WINDOWS EXTERIOR FRAME COLOR, GLASS
 GLAZING, LITE PATTERN, MUNTIN PROFILE AND MULLION
 WIDTH. A PHOTO OF EACH ELEVATION WITH EACH WINDOW
 MARKED.
 3. A HORIZONTAL ROLLER IS INAPPROPRIATE WINDOW TYPE
 REPLACEMENT FOR SINGLE-HUNG/AWNING WINDOWS. REVISE TO
 SINGLE-HUNG OR PAIRED SINGLE-HUNG AS REQUIRED TO MATCH
 EXISTING. A 1-INCH, 2-INCH, OR 3-INCH MULLION MAY BE
 REQUIRED TO MATCH THE EXISTING MULLION WIDTH.
 4. INDICATE COLOR OF EXTERIOR WINDOW FRAMES. ANODIZED
 OR WHITE. ANODIZED IS STRONGLY ENCOURAGED.
 5. REVISE WINDOWS #2, #3, AND #4 TO MATCH THE EXISTING
 WINDOWS PORTIONS AND HAVE A MULLION TO MATCH. A 2-INCH
 WIDE MULLION MAY BE REQUIRED. THIS SERIES OF WINDOW CAN
 BE A CASEMENT-FIXED-CASEMENT (PREFERRED),
 FIXED-FIXED-FIXED, OR AN XOX HORIZONTAL ROLLER. A
 4-LITE PATTERN WITH CGI SENTINEL?S LOW-PROFILE EXTERNAL
 MUNTIN WILL BE REQUIRED TO RECREATE THE APPEARANCE OF
 THE AWNING WINDOWS.
 6. THE FRONT DOOR SIDELIGHTS INDICATED AS 1A AND 1B
 MUST HAVE A 6-LITE PATTERN TO REPLICATE THE EXISTING.
 PLEASE CONFIRM THE LOW PROFILE MUNTIN IS AVAILABLE FOR
 THIS SPECIFIC PRODUCT.
 7. ALL SINGLE-HUNG WINDOWS WHEN REPLACING AN EXISTING
 4-AWNING WINDOW SHALL HAVE A HORIZONTAL 2/2 LITE
 PATTERN WITH CGI?S LOW-PROFILE EXTERNAL MUNTIN. ALL
 CASEMENTS WHEN REPLACING AN EXISTING 2-AWNING WINDOW OR
 A SINGLE-HUNG SHALL HAVE A CENTER LOW-PROFILE EXTERNAL
 MUNTIN. PROVIDE REVISIONS AS NECESSARY.
  
 PROPOSED CONDITIONS, SUBJECT TO CHANGE:
 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND
 MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL
 WINDOWS.
 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED
 WITH A MULLION OF MATCHING WIDTH AND PLACEMENT.
 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR.
 ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR
 WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS
 MAY BE USED ON NON-STREET FACING BATHROOMS ONLY.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES
 PLANNING DIVISION
 [email protected] | OFFICE: 561.822.1428 | TTY:
 800.955.8771
 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH,
 FL 33402
  