Plan Review Notes
Plan Review Notes For Permit 20120513
Permit Number 20120513
Review Stop P
Sequence Number 2
Notes
Date Text
2021-04-28 15:51:212ND REVIEW FBC-2017 PLUMBING
 PERMIT- 20120513
 4/28/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS #2 & 3 PRINTED
 BELOW FROM THE 1ST REVIEW STILL EXIST- PLEASE COMPLY.
  
 2) PROVIDE SANITARY DRAINAGE AND WATER SUPPLY ISOMETRIC
 DRAWINGS FOR THE REMODELED KITCHEN AND MASTER BATH-
 SECTION 107.3.5.1.3 WPB. BASED ON THE EXISTING AND
 REMODELED MASTER BATH FLOOR PLAN DRAWINGS IT APPEARS
 NEW DRAIN AND VENT PIPES WILL HAVE TO BE INSTALLED FOR
 THE NEW DOUBLE BOWL VANITY SINK. PLEASE PROVIDE THE
 SANITARY DRAINAGE ISOMETRIC AS REQUESTED IN THE 1ST
 REVIEW.
  
 3) PROVIDE A MASTER BATH SHOWER PAN DETAIL- SECTION
 421.5.2 FBC P. PLEASE SHOW THE SLOPE OF THE LINER IN
 THE DETAIL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  