2020-12-18 14:30:22PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THIS PROJECT IS LOCATED IN A HIGH RISE BUILDING.
 PLEASE SUBMIT DIGITALLY SIGNED AND SEALED COMPONENT &
 CLADDING PRESSURES FOR THE TWO SLIDING GLASS DOORS FROM
 A FLORIDA LICENSED ENGINEER. THE WIND SPEED IS 170 MPH
 AND THE EXPOSURE CATEGORY IS D. FBC 107.2.1.2
  
 2) CIRCLE OR HI-LIGHT THE ITEMS IN THE PRODUCT APPROVAL
 THAT APPLY TO THIS PROJECT, INCLUDING THE DESIGN
 PRESSURES FOR THE SPECIFIC DOORS THAT WILL BE
 INSTALLED. NOT: THE DESIGN PRESSURES FOR THE DOORS MUST
 BE GREATER THAN THE COMPONENT AND CLADDING PRESSURES
 DETERMINED BY THE ENGINEER. FBC 107.2.1
  
 3) SPECIFY THE HEIGHT OF THE BUILDING AND THE WALL ZONE
 THAT EACH OF THE DOORS IS LOCATED IN. FBC CHAPTER 16