Plan Review Notes For Permit 20120439 |
Permit Number |
20120439 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2021-03-04 09:36:09 | INTERIOR OFFICE BUILDOUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) NEW DRAWING A4.21 SHOWS TOILET PAPER DISPENSER | | DISTANCE FROM TOILET INCORRECTLY - SHOULD BE 7" TO 9" | | TO THE CENTER LINE OF THE DISPENSER FBC 604.7 (DRAWING | | A0.04 NEEDS TO BE CORRECTED ALSO). | | 2) NEW DRAWING A4.21 PLEASE SHOW THE REQUIRED 18" (DOOR | | MANEUVERING CLEARANCE) BESIDE THE DOOR TO ENTER THE | | ACCESSIBLE MEN'S ROOM TOILET COMPARTMENT FBC 404.2.4 |
|