Plan Review Notes
Plan Review Notes For Permit 20120003
Permit Number 20120003
Review Stop B
Sequence Number 1
Notes
Date Text
2020-12-08 14:24:44WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20120003
 ADD: 2400 S DIXIE HWY.
 CONT: BUTLER CONSTRUCTION
 TEL: 561-832-9700
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. DEC. 08TH/2020
 ACTION: DENIED
  
 1) MISSING CODE DATA NOT FOUND ON THE PLANS, NO LIFE
 SAFETY SHEET.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
  
 1A) MISSING CODE DATA:
 OCCUPANCY GROUP OLD AND PROPOSED NEW
 CHANGE OF OCCUPANCIES FOR A WHOLE BUILDING WOULD
 REQUIRE THE PLANS DESIGNED TO THE 2017 FBC-EXISTING
 BUILDING CODE, CHAPTER 10, AND SECTION 1001.2.2, FOR A
 FULL BUILDING.
  
 1B) MINIMUM TYPE OF CONSTRUCTION SECTION 503
 FIRE SPRINKLERED OR NOT
 FIRE RESISTANCE SEPARATION
 FIRE-RESISTANT SEPARATIONS
 FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION
 PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS
 FIRE BLOCKING AND DRAFT STOPPING AND CALCULATED FIRE
 RESISTANCE
  
 1C) FIRE SUPPRESSION SYSTEMS SHALL INCLUDE:
 EARLY WARNING SMOKE EVACUATION SYSTEMS
 SCHEMATIC FIRE SPRINKLERS
 STANDPIPES
 PRE-ENGINEERED SYSTEMS
 RISER DIAGRAM
  
 1D) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
 OCCUPANCY LOAD
 GROSS
 NET
 MEANS OF EGRESS
 EXIT ACCESS
 EXIT
 EXIT DISCHARGE
 STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION
 DOORS
 EMERGENCY LIGHTING AND EXIT SIGNS
 SPECIFIC OCCUPANCY REQUIREMENTS
 CONSTRUCTION REQUIREMENTS
  
 2) SHEET A002 SITE DETAILS / ACCESSIBLE STALL PARKING.
 THE DETAIL DOES NOT MEET THE CITY STANDARD FOR
 ACCESSIBLE PARKING SPACES, PLEASE REVIEW CITY OF W. P.
 B. STANDARD LINES ARE 4 INCHES WIDE WITH 12 INCHES/ 1
 FOOT BETWEEN LINES.
 ACCESSIBLE PARKING SPACE / STALL PAINTING.
  
 2A) 2017 ACCESSIBILITY CODE SECTION 502.2 VEHICLE
 SPACES. EACH PARKING SPACE MUST BE AT LEAST 12 FEET
 WIDE, SHALL BE MARKED TO DEFINE THE WIDTH, AND SHALL
 HAVE AN ADJACENT ACCESS AISLE COMPLYING WITH 502.3.
 ADVISORY 502.3.3MARKING THE METHOD AND MARKING OF COLOR
 OF MARKING ARE NOT SPECIFIED BY THESE REQUIREMENTS BUT
 MAY BE ADDRESSED BY STATE OR LOCAL LAWS OR REGULATIONS.
 WEST PALM MUNI-CODE ARTICLE XV PARKING DETAIL, 94-485
 ILLUSTRATES WITH MEASUREMENTS FOR DOUBLE STRIPE STALL
 PAINTING.
  
 2B) IN THESE DETAILS THE ELEVATIONS ARE NOT GIVEN AT
 THE CORNERS OF THE ACCESSIBLE PARKING SPACE AND
 ADJACENT ACCESS AISLE.
 2017 FBC-ACCESSIBILITY CODE 502.4 ACCESS AISLE &
 PARKING SPACE SAME LEVEL/ 502.4, FLOOR AND GROUND
 SURFACES. PARKING SPACES AND THE ACCESS AISLES SERVING
 THEM SHALL COMPLY WITH 302. ACCESS AISLES SHALL BE AT
 THE SAME LEVEL AS THE PARKING SPACES THEY SERVE.
 CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTION: SLOPES
 NOT GREATER THAN 1:48 SHALL BE PERMITTED.
  
 3) SHEET A101:
 3A) SHEET A101 IT IS ASSUMED TO BE THE PROPOSED LAYOUT
 OF THE BASEMENT PLAN. NO LIFE SAFETY INFORMATION WAS
 PROVIDED FOR THIS REVIEW. THE BASEMENT PLAN DOES NOT
 SHOW THE COMMON PATH OF TRAVEL FROM THE FURTHEST POINT
 TIN THE BASEMENT TO THE HEAD OF THE STAIRS AT WHICH YOU
 HAVE 2 CHOICES OF EXIT TRAVEL, PLEASE SHOW COMPLIANCE
 WITH THE 2017 FBC-B TABLE 1006.3.2(2).
  
 3B) THERE IS NO INFORMATION ON THE STAIRWAY AND
 HANDRAILS IF THEY ARE EXISTING AND THE RISE / RUN OF
 THE STAIRS NOR IF THERE IS ANY HANDRAILS. SEE THE 2017
 FBC-EXISTING BUILDING CODE SECTION 1012.4.2.
  
 4) SHEET A102 THE PROPOSED 1ST FLOOR PLAN:
 4A) THE PLANS DO NOT SHOW WHICH EGRESS DOORS ARE
 ACCESSIBLE EXITS. 2017 FBC-ACCESSIBILITY CODE SECTION
 207.1 MEANS OF EGRESS SHALL COMPLY WITH SECTION
 1003.2.13 OF THE INTERNATIONAL BUILDING CODE (2000
 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF THE
 INTERNATIONAL BUILDING CODE (2003 EDITION).
  
 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS
 IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY
 ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE
 SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS.
  
 4B) THE PLANS DO NOT SHOW COMPLIANCE WITH SECTION
 1007.1.1 OF THE 2017 FBC-B, TWO EXITS AND OR EXIT
 ACCESS DOORWAYS.
 WHERE 2 EXIT OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM
 ANY PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A
 DISTANCE APART EQUAL TO NOT LESS THAN ? THE OVERALL
 MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR
 AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN
 THEM.
 EXCEPTION BUILDINGS EQUIPPED THROUGHOUT WITH AN
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL
 NOT BE LESS THAN 1/3RD OVERALL DIAGONAL DIMENSION OF
 THE BUILDING OR AREA TO BE SERVED MEASURED IN A
 STRAIGHT LINE BETWEEN THEM.
  
 4C) PLEASE REVIEW THE STAIRWAY THAT LEADS FORM THE
 BASEMENT. THE 2017 FBC-B SECTION 1019.3 WOULD REQUIRE
 THE STAIRWAY TO BE ENCLOSED WITH A SHAFT ENCLOSURE
 CONSTRUCTED IN ACCORDANCE WITH 713. DOORS WILL NEED TO
 SHOW COMPLIANCE WITH 713.7 & 716 FOR FIRE BARRIER.
 DOORS SHALL BE SELF OR AUTOMATIC CLOSING BY SMOKE
 DETECTION IN ACCORDANCE WITH 716.5.9.3.
  
 4D)(1) THE PROPOSED FLOOR PLAN SHOWS A NEW 800 SQ. FT.
 WALK IN COOLER. PLEASE NOTE WALK IN COOLERS REQUIRE A
 SEPARATE PERMIT, REVIEW AND ASSOCIATED FEES. THEY ARE
 ALSO PART OF THE COMPONENTS AND CLADDING OF THE
 BUILDING AND REQUIRE PRODUCT APPROVALS. 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS: (31)(G) EXTERIOR COOLER, FREEZERS
  
 4D)(2) *00 SQ. FT. COOLERS WILL ALSO NEED TO SHOW
 COMPLIANCE WITH THE 2017 FBC-B SECTION 2603.4.1.2 AND
 2603.4.1.3.
  
 4E) THE PLAN INDICATES THERE IS 110 INDOOR SEATS. THE
 FLOOR PLAN DOES NOT SHOW ANY ACCESSIBLE SEATING. PLEASE
 SHOW COMPLIANCE WITH THE FOLLOWING ACCESSIBILITY
 REQUIREMENTS:
  
 4E)(1) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902. 110X0.05= 6SEATS.
  
 4E)(2) 226.2 DISPERSION. DINING SURFACES AND WORK
 SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 4E)(3) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN
 RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL
 BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR
 SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 4E)(4) 902.1 .DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK
 SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS,
 STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER
 TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORKSTATIONS (CHECK-OUT COUNTERS).
  
 4E)(5)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR
 FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 4E)(5)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 4F) PLEASE LOOK AT DOORS 12 & 13 MISSING MANEUVERING
 CLEARANCES AT DOORS. ACCESS. CODE 404.2.4 MANEUVERING
 CLEARANCES. DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL
 COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL
 EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE FOR SIDE CLEARANCE.
  
 4G) PLEASE NOTE THE EXTERIOR DOOR LOCATED BY THE HAND
 SINK AND OLE HICKORY IS A INSWING DOOR THE OCCUPANT
 LOAD OF THE BUILDING IS WELL OVER 50. 2017 FBC-B
 1010.1.2.1. DIRECTION OF SWING. PIOT OR SIDE-HINGED
 SWINGING DOORS SHALL SWING IN THE DIRECTION OF EGRESS
 TRAVEL WHERE SERVING ROOMS OR AREAS CONTAINING AN
 OCCUPANT LOAD OF 50 OR MORE.
  
 5) SHEET A104 ENLARGES RESTROOM FLOOR PLAN &
 ELEVATIONS:
 5A) THERE IS NO FINISHES SHEET FOR FLOORS, WALLS &
 CEILINGS. SHEET A104 IN THE SOUTH ELEVATION OF THE MENS
 RESTROOM STATES LINE OF SMOOTH, HARD, NONABSORBENT
 SURFACES ABOVE THE FLOOR. 2017 FBC-B 1210.2.2. WALLS &
 PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING
 OFFICIAL INTERPRETATION. IN RESTROOMS EPOXY PAINT IS NO
 LONGER CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE.
  
 5A)(1) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF
 SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A
 SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT
 LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL
 ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A
 TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 5A)(2) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET
 WALLS SHALL COMPLY WITH 1210.2.
  
 5A)(3) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS
 AND PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY
 WITH SECTIONS 1210.1 THROUGH 1210.4.
  
 5B) WITHIN THE LADIES RESTROOM WHEN THE BABY CHANGING
 TABLE IS IN THE DOWN POSITION YOU DO NOT HAVE THE
 MANEUVERING CLEARANCES AT DOOR # 07. ACCESS. CODE
 404.2.4 MANEUVERING CLEARANCES. DOORS.
 MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL
 COMPLY WITH 404.2.4. MANEUVERING CLEARANCES SHALL
 EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED
 LATCH SIDE FOR SIDE CLEARANCE. FIGURE 404.2.4.1(A).
  
 5C) IN BOTH THE MENS AND WOMENS RESTROOMS THE HEIGHT
 ABOVE THE FLOOR IS NOT GIVEN, SHOW COMPLIANCE WITH
 603.3 MIRRORS. 2017 FBC-ACCESSIBILITY CODE. MIRRORS
 LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE
 INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 5D) THE TOILET PAPER DISPENSER DOES NOT COMPLY WITH THE
 DISTANCE FROM THE FRONT OF THE WATER CLOSET. TOILET
 PAPER DISPENSERS. 604.7. THE TOILET PAPER DISPENSER
 SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM
 TO 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER.
  
 5E) THE ELEVATIONS FOR BOTH THE MENS AND LADIES
 RESTROOMS DEPICT THE GRAB BARS DIMENSIONED FROM THE
 CENTER LINE. PLEASE NOTE THE 2017 FBC-ACCESSIBILITY
 CODE SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS
 SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES
 MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR
 MEASURED TO THE TOP OF THE GRIPPING SURFACE, NOT
 CENTERLINE.
  
 5F) THE ELEVATIONS FOR BOTH THE MENS AND LADIES
 RESTROOMS DEPICT THE LAVATORY WITH A PROTECTION BOARD
 FOR PREVENTING EXPOSED PIPES IN COMPLIANCE WITH 606.5.
 WHAT IS MISSING FROM THE DETAIL IS COMPLIANCE WITH
 306.2 CLEARANCES FOR TOES AND 306.3 CLEARANCES FOR
 KNEES.
  
 5G) WHAT DETAILS FOR ACCESSIBILITY WERE NOT PROVIDED
 AND OR EXCEPTION ARE FOR DRINKING FOUNTAINS.
 5G)(1) 602.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 5G)(2) SPOUT OUTLETS/ DRINKING FOUNTAINS. 2017 ACCESS.
 CODE. SPOUT OUTLETS SHALL COMPLY WITH:
 602.4 SPOUT HEIGHT. 36 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND FOR WHEELCHAIR BOUND INDIVIDUALS.
 602.7 SPOUT HEIGHT FOR THE STANDING PERSONS SHALL BE
 BETWEEN 38 TO 43 INCHES ABOVE FINISH FLOOR.
  
 5G)(3) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS
 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES
 AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT
 PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE
 CIRCULATION PATH.
  
 6) SHEET S101 THE ROOF FRAMING PLAN. THE WIND DESIGN
 CRITERIA ARE GIVEN ON THIS PLAN WHAT IS MISSING IS THE
 MEAN ROOF HEIGHT. WIND EXPOSURE. APPLICABLE WIND
 DIRECTION IF MORE THAN ONE WIND EXPOSURE IS UTILIZED.
 TABLE 1609.7.2. HEIGHT AND EXPOSURE. ASCE 7-10 TABLE
 30.3.1. THE ELEVATIONS ON THE 200 SERIES OF DRAWINGS
 SHOWS THE ROOF AT 29.0 + PARAPET APPROX.. 30 FEET.
  
 7) THE COMPONENT AND CLADDING PRESSURES FOUND ON S302
 FOR THE ROOF AND WALL ZONES ARE GIVEN IN VASD. THANK
 YOU. THE WALL PRESSURES ARE UP TO 9.0 LBS. LOW PER PSF.
 WE ARE TAKING THE PRESSURES FROM AN ENGINEERS SPREAD
 SHEET FOR WALL COMPONENTS & CLADDING AND COMPARING TO
 ASCE 7-10 FIGURE 30.5.1, AS WELL AS THE PRESSURES FOUND
 IN THE 2017 RESIDENTIAL CODE THE SIMPLIFIED TABLE
 R301.2(2).
  
 8) WELDED OR BOLTED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 REPORTS SUBMITTED TO BUILDING INSPECTOR AT TIME OF
 FRAMING INSPECTION.
 2017 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR KEN CONRAD
 AT 561-805-6666.
  
 9) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS.
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP CURBS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 10) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 11) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 12) THE ROOF TOP A/C STAND PRODUCT APPROVALS, TO BE
 REVIEWED BY THE DESIGNER OF RECORD. PLEASE IDENTIFY THE
 FOLLOWING REQUIREMENTS CALCULATING THE AREA (SIDE VIEW)
 OF THE ROOF TOP COMPRESSORS, CONFIGURATION ON STAND,
 THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS,
 WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES,
 ANCHORS AND UPLIFT VERSES MOMENT FOR THE UNIT TO THE
 STAND AND THE STAND TO THE ROOF. THE PRODUCT APPROVAL
 IS TO BE REVIEWED BY THE DESIGNER OF RECORD, APPROVED
 BEFORE SUBMISSION TO THE BUILDING DEPARTMENT.
  
 13) 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF
 THIS SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 14) 2017 FBC-M 306.5 EQUIPMENT AND APPLIANCES ON ROOFS
 OR ELEVATED STRUCTURES. WHERE EQUIPMENT REQUIRING
 ACCESS OR APPLIANCES ARE LOCATED ON AN ELEVATED
 STRUCTURE OR THE ROOF OF A BUILDING SUCH THAT PERSONNEL
 WILL HAVE TO CLIMB HIGHER THAN 16 FEET (4877 MM) ABOVE
 GRADE TO ACCESS SUCH EQUIPMENT OR APPLIANCES, AN
 INTERIOR OR EXTERIOR MEANS OF ACCESS SHALL BE PROVIDED.
 SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER
 OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) IN HEIGHT
 OR WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE).
 SUCH ACCESS SHALL NOT REQUIRE THE USE OF PORTABLE
 LADDERS. WHERE ACCESS INVOLVES CLIMBING OVER PARAPET
 WALLS, THE HEIGHT SHALL BE MEASURED TO THE TOP OF THE
 PARAPET WALL.
  
 15) IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE
 REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA
 PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  
 16) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  