Plan Review Notes For Permit 20111031 |
Permit Number |
20111031 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2021-03-29 08:52:12 | CONDO BATH REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) MUST SHOW A FIRE CLASSIFICATION OF "C" FBC 803.1.1 | | INTERIOR WALL AND CEILING FINISH MATERIALS. | | INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE | | CLASSIFIED IN ACCORDANCE WITH ASTM E84 OR UL 723. SUCH | | INTERIOR FINISH MATERIALS SHALL BE GROUPED IN THE | | FOLLOWING CLASSES IN ACCORDANCE WITH THEIR FLAME SPREAD | | AND SMOKE-DEVELOPED INDEXES. | | | | CLASS A: = FLAME SPREAD INDEX 0-25; SMOKEDEVELOPED | | INDEX 0-450. | | CLASS B: = FLAME SPREAD INDEX 26-75; SMOKEDEVELOPED | | INDEX 0-450. | | CLASS C: = FLAME SPREAD INDEX 76-200; SMOKEDEVELOPED | | INDEX 0-450. |
|