Plan Review Notes
Plan Review Notes For Permit 20110707
Permit Number 20110707
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-11-25 10:25:02CANOPY WITH VERTICAL SUPPORT ALONG 8TH STREET- CANNOT
 HAVE VERTICAL ELEMENTS WITHIN MINIMUM SETBACK.
 AWNINGS AND CANOPIES TO BE REVIEWED THROUGH SEPARATE
 PERMIT
  
 PLEASE UPDATE CALC FOR "TOTAL COVERED ROOF STRUCTURES
 PER DEFINITION" AND "TOTAL OVERED STRUCTURES AREA" TO
 REFLECT NEW COVERED HALL ON SHEET A0.08
  
 PLEASE SUBMIT UPDATE TO LANDSCAPE PERMIT FOR
 MODIFICATIONS (DUMPSTER ENCLOSURE) FOR PLAN CONSISTENCY
 AND FOR UPDATES TO ROOF GARDEN
  
 PLEASE SUBMIT SHEET A4.15 FOR BAR PLAN. MUST BE OPEN
 AIR, NOT COVERED, AND NOT CLIMATE CONTROLLED PER
 SECTIONN 94-109 COVERED STRUCTURE DEFINTION. IF THE BAR
 AREA IS COVERED, THIS WOULD COUNT TOWARDS 30% OF
 COVERED STRUCTURE PERMITTED. CANNOT BE ENCLOSED
  
 PLEASE SUBMIT A PERMIT FOR INSTALLATION OF STREET LIGHT
 POLES PRIOR TO INSTALLATION OF ANY POLES. PLEASE
 INCLUDE A LANDSCAPE PLAN THAT INCLUDES THE LOCATION OF
 THE LIGHT POLES TO ENSURE NO CONFLICTS WITH STREET
 TREES. PLEASE INCLUDE LIGHT POLE SPEC (CONTACT CITY CRA
 AND ENG. FOR APPROPRRIATE LIGHT POLE FOR THIS
 STREETSCAPE)
  
 PLEAE EVALUATE - IS THERE OTHER MEANS OTHER THAN
 DOWNNSPOUTS FOR STORMWATER COLLECTION?
  
 MINOR SUBDIVISION FOR REPLAT IS REQUIRED PRIOR TO CO -
 PLEASE SUBMIT THROUGH P&Z
  
 WHAT APPEARST TO BE LARGE EXHAUST FAN ON NORTH SIDE OF
 BUILDING THAT APPAERAS ON SHEET A3.03 IS NOT INDICATED
 ON NORTH ELEVATION SHEET A2.01. PLEASE INCLUDE. CAN
 THIS BE SCREENED? CAN THIS BE PAINTED?
 PLEASE EVALUATE AND PROVIDE RESPONSES. ALSO PLEASE
 INCLUDE ON SHEET A3.04
  
 UPDATE LABEL FOR MECHANICAL WELL SECTION ON SHEET A3.10
 - APPEARS A WINDOW PLACEMENT CHANGED BYT LABEL WAS NOT
 MODIFIED. WHAT WINDOW IS THIS ON THE ELEVATION? PLEASE
 RESPOND IN COMMENT RESPONSE MEMO
  
 EXHAUST HOOD AS SHOWN ON EAST FACADE-WALL SECTION ON
 SHEET A3.10 DOES NOT SEEM TO APPEAR ON ELEVATIONS.
 PLEASE INDICATE AND INCLUDE DETAIL OF SCREENING.
  
 ADA PARKING SIGN CANNOT BE WITHIN 2 FOOT OVERHANG
  
 ARE THERE TWO GENERATORS NOW? GENERATOR UP AGAINST
 SIDEWALK IS NOT IDEAL. PLEASE EVALUATE OTHER LOCATIONS.
 PLEASE PROVIDE ENCLOSURE DETAILS FOR GENERATOR UP
 AGAINST SIDEWALK. HEIGHT, MATERIALS, ETC. - WILL NEED
 TO BE EVALUATED FOR SCREENING
  
 IS NOTE NUMBER 32 BACKFLOW ASSEMBLY TO SERVE THE
 BUILDING? CAN THIS BE RELOCATED ALONG THE INTERNAL
 DRIVE? PLEASE EVALUATE AND DISCUSS WITH MARK HURLEY IN
 PUBLIC UTILITIES AND WITH ZONING
  
 WHAT IS THE MEANING OF THE "X" SYMBOL ON THE FENCE
 DETAILS?
  
 PROPOSED PROVISOS:
 PANIC GATE DESIGNED BY ARTIST TO BE SUBJECT TO PERMIT
 REVISION ONCE DETAIL HAS BEEN SELECTED
  
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426
  
  
  
  
  
  
  
  